NYC-WTC_000270259
TEM analysis data for NSHS exterior received 10/06/01.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗TEM analysis data for NSHS project, exterior/interior, received 10/15/01.
NYC-WTC_000293545OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/15/01
ASBESTOS FIBER TkNALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method; AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, Ho. 210, October 30, 1987
Sample Identification Analysis Parameters
Pre3ect/Site-. New Stuyvesant H.E., 345 Chambers St., NY, NY TEM Sample No.: 5691 61074 Exterior & Interior of Building & Roof Date Received; 10/152^ Grid Openings Analyzed;__ 4
Project Sample No. ; NSHS-EIR-lO/14-06 Average Grid Opening:^;0^6^££um
Air Volume: 1899 liters Total Area Analyzed : 0..j0£5£mm2
Filter Type :' Analytical Sensitivity;22^2 s2mm2 Effective Area: 3a5mm2 O.D045 s/cc
FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5uTn Struct/mm2 Struct/cc ngn/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 c 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CITY_21MC100_003082199
NYC-WTC_000293545
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000270259
TEM analysis data for NSHS exterior received 10/06/01.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293781
TEM analysis for New Stuyvesant H.S. exterior & interior; received 10/21/01.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188704
Document recording transmission electron microscopy results for asbestos fiber identification in air samples from a high school building.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293448
TEM analysis data for NSHS; exterior/interior openings documented.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270459
TEM analysis data for New Stuyvesant H.S. exterior/interior samples, 5698-61334.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270973
TEM asbestos analysis with SAED/EDS for New Stuyvesant HS exterior/interior, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270979
TEM asbestos analysis with SAED/EDS for New Stuyvesant High School, received 10/28/01.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294008
TEM analysis of air samples at New Stuyvesant H.S., Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293420
Asbestos TEM analysis with SAED/EDS for New Stuyvesant HS site, 10/09/01.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293567
TEM analysis of air at Stuyvesant HS with opening size and area details per AHERA method.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188694
Document containing transmission electron microscopy data for asbestos fiber identification in air samples from a high school building.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293649
TEM analysis including SAED/EDS; exterior/interior assessment at New Stuyvesant HS; sample 5725.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000270259
TEM analysis data for NSHS exterior received 10/06/01.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293781
TEM analysis for New Stuyvesant H.S. exterior & interior; received 10/21/01.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188704
Document recording transmission electron microscopy results for asbestos fiber identification in air samples from a high school building.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293448
TEM analysis data for NSHS; exterior/interior openings documented.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270459
TEM analysis data for New Stuyvesant H.S. exterior/interior samples, 5698-61334.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270973
TEM asbestos analysis with SAED/EDS for New Stuyvesant HS exterior/interior, Oct 2001.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000270259
TEM analysis data for NSHS exterior received 10/06/01.
Similar indexed content
TEM analysis for New Stuyvesant H.S. exterior & interior; received 10/21/01.
Similar indexed content
NYC-WTC_000188704
Document recording transmission electron microscopy results for asbestos fiber identification in air samples from a high school building.
Similar indexed content
NYC-WTC_000293448
TEM analysis data for NSHS; exterior/interior openings documented.
Similar indexed content
NYC-WTC_000270459
TEM analysis data for New Stuyvesant H.S. exterior/interior samples, 5698-61334.
Similar indexed content