NYC 9/11 Public Portal Document

Protection from Chemical, Biological, or Radiological Attacks 13

systems should be isolated and the areas maintained at a neg­ ative pressure relative to the rest of the building, but at posi­ tive pressure relative to the outdoors. Physical isolation of these areas (well-sealed floor to roof-deck walls, sealed wall penetrations) is critical to maintaining the pressure differen tial and requires special attention to ensure airtight bound­ aries between these areas and adjacent spaces. In some build­ ing designs (those having lobbies with elevator access, for example), establishing a negative pressure differential will present a challenge. A qualified HVAC professional can assist in determining if the recommended isolation is feasible for a given building. In addition, lobbies, mailrooms, and loading docks should not share a return-air system or return pathway (e.g., ceiling plenum) with other areas of the building. Some of these measures are more feasible for new construction or buildings undergoing major renovation.

Building access from lobby areas should be limited by securi­ ty checks of individuals and packages prior to their entry into secure areas. Lobby isolation is particularly critical in build­ ings where the main lobbies are open to the public. Similar checks of incoming mail should also occur before its con­ veyance into the secure building areas. Side entry doors that circumvent established security checkpoints should be strictly controlled.

6. Secure return air grilles. Similar to the outdoor-air intake, nVAC return-air grilles that are publicly accessible and not easily observed by security may be vulnerable to targeting for CBR contaminants. Public access facilities may be the most vulnerable to this type of CBR attack. A building-security assessment can help determine, which, if any, protective measures to employ to secure return-air grilles. Take caution that a selected measure does not adversely affect the perform­ ance of the building HVAC system. Some return-air grille

CITY_21MC100_011104384

NYC-WTC_000291448

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000291448Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000127738 · Box DEP Box 52

Health and safety plan for Phase I deconstruction at 133-135 Greenwich Street and 21-23 Thames Street dated June 8, 2005.

Similar indexed content

NYC-WTC_000279102

Building Department memo/guide related to emergency planning after 9/11.

Similar indexed content

Compare copies and versions →