Concrete report, LIRO NYC DDC 6/5/2002

Machine-extracted title · confidence 28%

Concrete test report for WTC project; LIRO NYC DDC; May–June 2002.

NYC-WTC_000290442
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

MUNICIPAL TESTING LABORATORY, INC. 102 NEW SOUTH ROAD, HICKSVILLE, NEW YORK 11801, 516-938-7120, 516 938-5107 FAX S SSB sassss CONCRETE REPORT lient: LIRO Group/NYC DDC Attn; Mike Bailey Report Date: 6/5/2002 Address: Six Aerial Way Report Number: D0965 Lab#: 1350 Syosset, NY 11791 Date Cast: 5/6/2002 Project: WTC Paving Project Contractor: Tully/'Grace Concrete Plant: N/A Strength PSI: NA Yards Placed: NA as FIELD INSPECTION REPORT

Pour Location for Set # 1; South on West Broadway, all raised heads from Franklin St. - South on Broadway

Pour Location for Set # 2; Pour Location for Set # 3; Tests made in accordance with ASTM; Yes Not Known Field Inspector(s); Client ASTM C 39 "" COMPRESSIVE STRENGTH TESTS ssssssss&ssssssssssssssss sssssssssssssssssssssassBszzssassssssssasssss AREA: 28.27 Cylinder Dia: 6" Cylinder Date Date Slump Air UnitWt. Temp F. Truck Tested Load Strength I Required Type IO# Cast Tested C143 C173, C231 C133 C1064 No. Age KN PSI I strength Frac Cylinder Set#1 6A 5/6/2002 5/13/2002 7 997.3 7,930 NA A 6B 5/6/2002 6/3/2002 28 1125.0 8,950 NA A 6C 5/6/2002 6/3/2002 28 1131.2 9,000 NA A

Cylinder Set #2

Cylinder Set #3

Remarks:

Cylinder Set # 1 Did Not Reach The Specified Strenqh

Reviewed By: Laboratory Director Richard Kasparian, P.E tests are conducted in accordance with ASTM C-39 or AASHTO T-22. By technicians certified by ACI. Municipal Testing is inspected by the Cement and Concrete Reference Laboratory of The National Institute of

Standards and Technology and is Accredited by: AASHTO and is Licensed by: New York City (#19) and by The State of Florida. This report relates only to the Item or exact location/ltem tested.

not to the entire construction. It can only be repreduced in full, and only with Municipal Testing Laboratory. Inc written permission. Our liability is strictly limited to the fee paid.

CITY_21MC100_001659448 NYC-WTC_000290442

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000290442Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →