Concrete field inspection, LIRO NYC DDC, 2002

Machine-extracted title · confidence 28%

Field inspection report for concrete elements on W.T.C. project; May 2002.

NYC-WTC_000290439
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

MUNICIPAL TESTING LABORATORY, INC. 102 NEW SOUTH ROAD, HICKSVILLE, NEW YORK 11801, 516-938-7120, 516 938-5107 FAX CONCRETE REPORT ient: LIRO Group/NYC DDC Attn: Mike Bailey Report Date: 5/30/02 ■ddress; Six Aerial Way Report Number: D0831 Lab#: 1153 Syosset, NY 11791 Date Cast: 4/26/02 Project: WTC Paving Project Contractor: Tully/Grace JV Concrete Plant: N/A Strength PSI: 3200 Yards Placed: 2 FIELD INSPECTION REPORT

Pour Location for Set # 1: Hudson Street & Franklin Street

Pour Location for Set # 2; Pour Location for Set # 3: Tests made in accordance with ASTM: Yes Not Known X Field Inspector (s) : Client ASTM C 39 COMPRESSIVE STRENGTH TESTS AREA; 28.27 Cylinder Dia 6" Cylinder Date Date Slump Air Unit Wt. Temp F. Truck Tested Load Strength Required Type ID # Cast Tested C143 ;173, C23 C138 C1064 No. Age KN PSI Strength Frac Cylinder Set # 1 003A 4/26/02 5/3/02 NA NA NA NA NA 7 1066.1 8,480 3,200 A 003B 4/26/02 5/24/02 NA NA NA NA NA 28 1098.9 8,740 3,200 A 003C 4/26/02 5/24/02 NA NA NA NA NA 28 1091.6 8,680 3,200 A

Cylinder Set # 2

Cylinder Set # 3

/'------------ L- f Remarks: Cylinders Made By Client

Reviewed By: Laboratory Directed Richard Kasparian, P.E ^||bets are conducted in accordance with ASTM C-39 or AASHTO T-22, By technicians certified by ACl. Municipal Testing is inspected by the Cement and Concrete Reference Laboratory of The National Institute of

^^Rrds and Technology and is Accredited by: AASHTO and is Licensed by; New York City (#19) and by The State of Florida. This report relates only to the item or exact location/item tested.

not to the entire construction. It can only be reproduced in full, and only with Municipal Testing Latxjratory. inc. written permission. Our liability is strictty limited to the fee paid.

CITY_2IMCl00_001659445 NYC-WTC_000290439

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000290439Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →