r Asbestos Certification Statement The final clearance levels for reoccupancy of the abatement area shall be 0.01 or fewer asbestos fibers per cubic centimeter if determined by Phase Contrast Microscopy Analysis (PCM) or 70 or fewer structures per square millimeter if determined by Transmission Electron Microscopy (TEM).

http://www.lhc.org.uk/members/pubs/books/asbestos/asb07.hfm Asbestos Removal The modem myth: asbestos removal is risky and a waste of money Asbestos Chapter 7 © London Hazards Centre, Interchange Studios, Dalby Street, London NW5 3NQ, UK

Monitoring and sampling Monitoring methods There arc three methods of assessing whether asbestos is present

Bulk sampling: involves taking a small sample of the material and it examining under a microscope. This is combined with a visual inspection to assess the condition of the material. This method is used in surveying bmldings and sites to determine if a material contains asbestos. With this information a prioritisation system for removal and control can be developed.

Wipe testing: involves taking a sample of" dust from the area and inspecting it under a microscope. Used when asbestos has been disrupted or removed as an essential back up to air monitoring. It shows if asbestos fibres have settled out of the air onto surfaces.

Air monitoring: involves drawing a sample of air through a filter by means of a pump, then counting die number of fibres trapped on the filter under the microscope. Used to check fibre levels in die air after removal or during disruption of asbestos materials.

Why air monitor? The vast majority of asbestos fibres that damage tlie lungs are invisible to the naked eye so air monitoring is an important method for detecting asbestos contamination. It must be carried out in a veiy precise way to be accurate. It is necessary in checking to sec whether asbestos has been safely removed. It can also be dangerously misleading, if not done properly by reputable firms working to the highest standards.

Air monitoring can be used to "blind you with science". Many tenants groups and workers have stones of employers and councils using air tests to "prove" that the asbestos in buildings is "safe," meaning that it is well below the control limits and action levels. But air tests can only measure the fibres floating in die air at tlie time the sample was taken, results could be thousands of times liighcr seconds later if the material is disturbed.

Air monitoring is no substitute for visual inspection and bulk sampling when diagnosing and assessing risk from asbestos.

Problems of collecting samples 1 Check how many tests are being earned out, the position of sampling units and their flow rates. If sampling heads are located far from the possible source of asbestos fibres they are unlikely to pick up any useful results, particularly when out of doors. Each sample is specific to a particular location at a particular time and is therefore not representative of all conditions at all times.

2 file size of the room or area is important in determining how many pumps to run. It is best to have two pumps per enclosure and three pumps for a space of 25 cubic metres, five for 50 cubic metres room and one additional sampler for every' extra 25 cubic metres.

3. Any air sampling should be accompanied by wipe tests and dust and debris sampling as the air may be within the acceptable limits but the settled dust and debris may still contain asbestos.

CITY_21MC100_011074928

NYC-WTC_000289578

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000289578Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Small fiber study: TEM vs OSC

NYC-WTC_000318625

Overview of TEM vs optical microscopy for asbestos fiber measurement and historical context.

Similar indexed content

Compare copies and versions →