NYC-WTC_000318755
Background report on asbestos and related contaminants for WTC environment, 1987.
27 shared non-person entities · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗Background study draft on asbestos in schools related to WTC, March 2003.
NYC-WTC_000318678–000318754OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Federal Register / Vol. 52, No. 210 / Friday, October 30, 1987 / Rules and Regulations 41893
1. When the samples arrive at the 2. "Measuring Airborne Asbestos the abatement area has passed a laboratory, check the samples and Following an Abatement Action," thorough visual inspection, and before documentation for completeness and USEPA/ Office of Toxic Substances. the outer containment barrier is requirements before initiating the EPA 600/4-85-049,1985. removed, a minimum of five air samples analysis. 3. Small, John and E. Steel. Asbestos inside the abatement area and a 2. Check all laboratory reagents and Standards: Materials and Analytical minimum of five air samples outside the supplies for acceptable asbestos Methods. N.B.S. Special Publication 619. abatement area must be collected. background levels. 1982. Hence, the response action is 3. Conduct all sample preparation in a 4. Campbell, W.J., R.L. Blake. L.L. determined to be completed when the clean room environment monitored by Brown, E.E. Cather, and J.J. Sjoberg. average airborne asbestos concentration laboratory blanks and special testing Selected Silicate Minerals and Their measured inside the abatement area is after cleaning or servicing the room. Asbestiform Varieties. Information not statistically different from the 4. Prepare multiple grids of each Circular 8751, U.S. Bureau of Mines, average airborne asbestos concentration sample. 1977. measured outside the abatement area. 5. Provide laboratory blanks with 5. Quality Assurance Handbook for The inside and outside concentrations each sample batch. Maintain a Air Pollution Measurement System. are compared by the Z-test, a statistical cumulative average of these results. If Ambient Air Methods, EPA 600/4-77- test that takes into account the this average is greater than 53 f/mm ® 027a, USEPA, Office of Research and variability in the measurement process. per 10 200-mesh grid openings, check the Development, 1977. A minimum of five samples inside the system for possible sources of 6. Method 2A: Direct Measurement of abatement area and five samples contamination. Gas Volume Through Pipes and Small outside the abatement area are required 6. Check for recovery of asbestos from Ducts. 40 CFR Part 60 Appendix A. to control the false negative error rate, cellulose ester filters submitted to 7. Burdette, G.J. Health & Safety Exec., i.e., the probability of declaring the plasma asher. Research & Lab. Services Div., London, removal complete when, in fact,, the air 7. Check for asbestos carryover in the "Proposed .Analytical Method for concentration inside the abatement area plasma asher by including a blank Determination of Asbestos in Air." is significantly higher than outside the alongside the positive control sample. 8. Chatfield, E.J., Chatfield Tech, abatement area. Additional quality 8. Perform a systems check on the Cons,, Ltd,, ClarIq T,, PEI Assoc, control is provided by requiring three transmission electron microscope daily. "Standard Operating Procedure for blanks (filters through which no air has 9. Make periodic performance checks Determination of Airborne Asbestos been drawn) to be analyzed to check for of magnification, electron diffraction Fibers by Transmission Electron unusually high filter contamination that and energy dispersive X-ray systems as Microscopy Using Polycarbonate would distort the test results. set forth in Table III of Unit UI.K. Membrane Filters." WERL SOP 87-1, 10. Ensure qualified operator When volumes greater than or equal March 5,1987. to 1,199 L for a 25 mm filter and 2,799 L performance by evaluation of replicate 9. NIOSH. Method 7402 for Asbestos for a 37 mm filter have been collected counting, duplicate analysis, and Fibers, December 11.1986 Draft, standard sample comparisons as set and the average number of asbestos 10, Yamate, G„ S,C- Agarwall, R,D, structures on samples inside the forth in Table UI of Unit III.K, Gibbons, IIT Research Institute, 11. Validate all data entries. abatement area is no greater than 70 "Methodology for the Measurement of s/mm of filter, the response action may 12. Recalculate a percentage of all Airborne Asbestos by Electron computations and automatic data be considered complete without Microscopy." Draft report, USEPA comparing the inside samples to the reduction steps as specified in Table III. Contract 68-02-3266, July 1964. 13. Record an electron diffraction outside samples. EPA is permitting this 11. Guidance to the Preparation of initial screening lest to save analysis pattern of one asbestos structure from Quality Assurance Project Plans. every five samples that contain costs ui situations where the airborne USEPA, Office of Toxic Substances, asbestos concentration is sufficiently asbestos. Verify the identification of the 1984. pattern by measurement or comparison low so that it cannot be distinguished of the pattern with patterns collected IV. Mandatory Interpretation of from the filter contamination/ from standards under the same Transmission Electron Microscopy background level (fibers deposited on conditions. Results to Determine Completion of the filter that are unrelated to the air The outline of quality control Response Actions being sampled). The screening test procedures presented above is viewed cannot be used when volumes of less A. Introduction than 1,199 L for 25 mm filter or 2,799 L as the minimum required to assure that quality data is produced for clearance A response action is determined to be for a 37 mm filter are collected because testing of an asbestos abated area. completed by TEM when the abatement the ability to distinguish levels Additional information may be gained area has been cleaned and the airborne significantly different from filter by other control tests. Specifics on those asbestos concentration inside the background is reduced at low volumes. control procedures and options abatement area is no higher than The initial screening test is expressed available for environmental testing can concentrations at locations outside the in structures per square millimeter of be obtained by consulting References 6, abatement area. "Outside" means filter because filter background levels 7, and 11 of Unit IIl.L. outside the abatement area, but not come from sources other than the air necessarily outside the building. EPA being sampled and cannot be L. References reasons that an asbestos removal meaningfully expressed as a For additional background contractor cannot be expected to clean concentration per cubic centimeter of information on this method the following an abatement area to an airborne air. The value of 70 s/mm’ is based on references should be consulted. asbestos concentration that is lower the experience of the panel of 1. "Guidelines for Controlling than the concentration of air entering microscopists who consider one Asbestos-Containing Materials in the abatement area from outdoors or structure in 10 grid openings (each grid Buildings," EPA 560/5-85-024, June 1985, from other parts of the building. After opening with an area of 0.0057 mm’) to
NYC-WTC_000318744
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000318755
Background report on asbestos and related contaminants for WTC environment, 1987.
27 shared non-person entities · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000449399
EPA Part 763 asbestos SOP excerpt with subparts and scope.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000451982
Chain-of-custody and SOP excerpt focusing on asbestos validation and PCB spiking.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434918
Continuation of the asbestos validation SOP text with definitions and scope.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445234
EPA Part 763 subpart I excerpt regarding asbestos, testing parameters and definitions.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000452898
Chain-of-custody excerpt referencing Part 763 asbestos procedures and compliance.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000433711
Page from Part 763 asbestos standard; references to testing and enforcement sections.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445985
Chain-of-custody excerpt referencing Part 763 sections and regulatory definitions.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000435395
Part 763 Subpart text related to asbestos standards and testing definitions.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000438164
EPA SOP excerpts and references for asbestos validation and inspections.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000442707
Pallet of Part 763 asbestos-related standard references and definitions.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434667
Environmental protection document detailing Part 763 asbestos definitions and related sections.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000389978
Policy language on clean areas, HEPA filtration, and sampling expectations for asbestos work.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445985
Chain-of-custody excerpt referencing Part 763 sections and regulatory definitions.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000451982
Chain-of-custody and SOP excerpt focusing on asbestos validation and PCB spiking.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000435395
Part 763 Subpart text related to asbestos standards and testing definitions.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000449399
EPA Part 763 asbestos SOP excerpt with subparts and scope.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000433711
Page from Part 763 asbestos standard; references to testing and enforcement sections.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000318755
Background report on asbestos and related contaminants for WTC environment, 1987.
Similar indexed content
NYC-WTC_000449399
EPA Part 763 asbestos SOP excerpt with subparts and scope.
Similar indexed content
NYC-WTC_000451982
Chain-of-custody and SOP excerpt focusing on asbestos validation and PCB spiking.
Similar indexed content
NYC-WTC_000434918
Continuation of the asbestos validation SOP text with definitions and scope.
Similar indexed content
NYC-WTC_000445234
EPA Part 763 subpart I excerpt regarding asbestos, testing parameters and definitions.
Similar indexed content