Asbestos glossary, lab report, 9/2001

Machine-extracted title · confidence 18%

Glossary and reference material on asbestos terms and regulations used for lab context.

NYC-WTC_000289570–000289579
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

NESHAP: National Emission Standard or Hazardous Air Pollutants (rev. 1996).

Non-asbcstiform; tending to break nto cleavage fragments having engtluwidlJi ratios from 2:! to 20:1.

OSH A: Occupational Safety & Health Administration; requires that workers be protected from asbestos exposure.

PCM: phase-contrast microscope, an optical microscope used to perfonn iber counts on air sample filters. Its disadvantages for asbestos analysis are that 1) it cannot resolve all asbestos fibers, and 2) it caimot distinguish asbestos fibers from other ibers.

PEL: permissible exposure limit; OSHA mandated maximum level for workers without respiratory protection (8 hour ime weighted average).

stnicturcs/mm2: asbestos stmetures, a.s defined by AHERA (fiber, bundle, matrix or cluster), per square millimeter of filter; reporting units for AHERA TE.M analyses.

TEM: transmission electron microscope, highly technical equipment used to perform asbestos analysis on air samples. It can resolve and distinguish all asbestos fibers from other fibers.

http://www.emsl.com/sampling_for_indoor_air_qualit.html EMSL Analytical is the world's largest laboratory devoted to the analysis of asbestos by electron microscopy. Established in 1981, EMSL became a pioneer in asbestos analysis, refining sample preparations techniques and laboratory practices. In 1984 in an effort to reduce the turnaround on TEM air samples we introduced the currently accepted but then critrzed 24 horn turnaround; in 1986, same day turnaround time and finally, in 1987, six hour turnaround time. Now EMSL offers 3 Hour Turnaound on TEM.

POLARIZED LIGHT MICROSCOPY Polarized Light Microscopy ( PLM) is the EPA accepted screening method for asbestos in bulks. However, it fails in samples where asbestos

CITY_21MC100_011074921

NYC-WTC_000289571

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000289571Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Small fiber study: TEM vs OSC

NYC-WTC_000318625

Overview of TEM vs optical microscopy for asbestos fiber measurement and historical context.

Similar indexed content

Compare copies and versions →