NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 10 pages

Asbestos glossary, lab report, 9/2001

Machine-extracted title · confidence 18%

Glossary and reference material on asbestos terms and regulations used for lab context.

NYC-WTC_000289570–000289579
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

fibers are fine or obscured by tightly binding inabix.

PHASE CONTRAST MICROSCOPY Phase Contrast Microscopy ( PCM) is used for measuring fibrous dust greater than 0.3 microns in diameter and greater than 5 microns in lengtli. This methodogy is not capable of identifying asbestos fibers or visualizing fibers less than 0.3 microns in diameter.

TRANSMISSION ELECTRON MICROSCOPY Transmission Electron Microscopy (TEM ) capable of Energy Dispersive X-Ray Microanalysis (EDX) and Electron Diffraction (SAED), is the most sophisticated analytical instrument available to us for the analysis of airborne and waterborne asbestos fibers. Transmission Electron Microscopy is also used for the analysis of asbestos in soils and bulk samples in general.

SCANNING ELECTRON MICROSCOPY Scanning Electron Microscopy and Energy Dispersive X-Ray Microanalysis(SEM / EDX) is suited for the analysis of asbestos in bulks, tapes, wipes, and for studying die structure and elemental composition of any materials in the solid state.

X-RAY DIEFRACTION X-Ray Diffraction (XRD) is used for the analysis of free silica, asbestos in bulks, for product identification and for the identification of crystalline phases in general.

Identifying tlie cause of an Indoor Air Quality problem or ’' Sick Building Syndrome" that is caused by particulate is rarely solved by air testing alone. Actually, air sampling only represents the particles in tlie air stream at the time of sampling. Furthermore, many problem materials, such as fibrous glass, settle quickly and are not adequately represented in an air sample. Testing the settled dust can reveal materials that air sampling may miss. Settled dust also represents the material that is present in the air over a longer period of time.

Sampling settled dust is relatively quick and simple. Three techniques are; the Glove-Bag or Scrape sampling, Micro-Vacuuming and Wipes.

Glove-Ba g/ Scrape sampljng is used when there is enough accumulation of dust that it can easily be placed into a bag or other shipping container. Generally, at least a teaspoon full.

Micro-Vacuuming consists of attaching an air sampling cassette to a vacuum pump. The cassette is equipped with a short piece of tubing (hat lias had the end cut and notched to a 45o angle. By sweeping the end of the tubing across an area the particles are trapped within the cassette and easily shipped. It is important to collect as much material as possible for accurate analysis. The volume of air and the area sampled are not of concern. Clear cassettes can make it easier to view the particle loading. Do not worry about clogging the filter, in fact, submitting a cassette tliat houses a large lint ball is preferable to a discoloration on die filter.

CITY_21MC100_011074922

NYC-WTC_000289572

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000289572Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Small fiber study: TEM vs OSC

NYC-WTC_000318625

Overview of TEM vs optical microscopy for asbestos fiber measurement and historical context.

Similar indexed content

Compare copies and versions →