NYC-WTC_000362551
Discussion of dioxin data, TEQ calculations, and reporting units for comparison to benchmarks.
2 shared non-person entities · similarity 0.942
machine-extracted · confidence unavailable · Check page ↗Correspondence discussing reporting of dioxin results and post-cleaning samples.
NYC-WTC_000281976–000281977OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Gilsenan, Michael From: Theodorellys, Penny Sent: Monday, December 09, 2002 11:47 AM To: 'sallemil [email protected]' Cc: Gilsenan, Michael; Radhakrishnan, Krish Subject: FW: FW: R02100403 Dioxin results
I realize you were co'ed on this message. Please report all results in your final report in accordance with the instructions received from USEPA. Don't hesitate to call me if you need to.
-----Original Message----- From: Nace.CharlesSepamail.epa.gov [mailto:Nace.Charlesgepamail .epa.gov] Sent: Monday, December 09, 2002 11:37 AM To: Theodorellys, Penny Cc: [email protected] ; Krish Radhakrishnan; [email protected]; [email protected]; LaPosta.DoreSepamail.epa.gov Sub/ect: Re: FW: R02100403 Dioxin results
Penny,
Sh R02100403 Cover R02100403 R02100403 TEQ Letter.rtf Report, rtf Report.xls Thanks for forwarding along the las f the post-cleaning dioxin samples for 125 Cedar Street. 1 was waiting for the complete package of post cleaning dioxin samples until I took a detailed look at them and I as I started to go through them tills morning I realized that the TEQs were calculated using a value of 0 when the result was non-detect, instead of using h of the detection limit for non-detect in the calculations. Could the TEQ results be recalculated using h of the detection limit for non-detects? Also, could the final reporting units for the TEQs be reported in she units of ng/m2 instead of pg? Thanks, Chuck Nace Environmental Toxicologist
USEPA - Region 290 oroaoway - 18th Floor ERRD/P3B/TST New York, NY 10007-1866 212.637.3459 212 7.4164 212.637.4360 - fax nace.charlesGepa.gov
"Theodorellys, Penny" To: Charles Nace/R2/USEPA/US@EPA <ptheodorellys@d co; ep.nyc.gov> Subject: FW: R021004C3 Dioxin results
12/09/2002 09:17 AM
1
CITY_21MC100_002941689
NYC-WTC_000281976
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000362551
Discussion of dioxin data, TEQ calculations, and reporting units for comparison to benchmarks.
2 shared non-person entities · similarity 0.942
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162494
EPA memo forwarding revised dioxin TEQ analytical results from environmental testing, with three sample reports recalculated per specifications.
1 shared non-person entities · 1 shared topics · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162688
Lab reports corrected dioxin TEQ results from wipe sampling, including non-detect adjustments and analytical methodology documentation pending.
2 shared non-person entities · similarity 0.938
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162505
Lab correspondence regarding receipt and status of dioxin wipe samples for analysis, with note that PAH wipe extractions were previously disposed of.
1 shared non-person entities · 1 shared topics · similarity 0.932
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000163072
Review of laboratory data for PAH, lead, and asbestos at 114 Liberty Street noting issues with reporting limits.
3 shared non-person entities · similarity 0.928
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000163108
Laboratory forwarding final PAH wipe analytical results with cover letters and reports to DEP and EPA for review.
1 shared non-person entities · similarity 0.922
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155098
Memo specifying that the final contract work and ledge clean-up were completed in late March 2003.
2 shared non-person entities · similarity 0.920
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162572
Correspondence sharing an updated spreadsheet tracking the status of HVAC systems across different quadrants of the World Trade Center site.
2 shared non-person entities · similarity 0.916
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000163085
Laboratory response explaining method detection limit versus practical quantitation limit for PAH analysis and confirmation that samples did not require reanalysis.
2 shared non-person entities · 1 shared topics · similarity 0.914
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000163137
Update on FEMA reimbursement deadlines and final payments for WTC interior cleanup contractors.
2 shared non-person entities · similarity 0.912
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000163082
DEP review of revised PAH laboratory results for 114 Liberty identifying concerns about detection limit consistency between original and revised analytical sheets.
2 shared non-person entities · similarity 0.907
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162521
Lab report forwarding final dioxin wipe results for first 20 post-event samples with TEQ calculations and detection limits.
2 shared non-person entities · 1 shared topics · similarity 0.904
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000362551
Discussion of dioxin data, TEQ calculations, and reporting units for comparison to benchmarks.
Similarity score 0.958 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369031
EPA COPC summary: pre/post-cleaning results; some areas exceeded numeric criteria.
Similarity score 0.937 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362726
Summary of analytical results for COPC-related samples; pre/post-cleaning results for WTC area.
Similarity score 0.936 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362551
Discussion of dioxin data, TEQ calculations, and reporting units for comparison to benchmarks.
Similarity score 0.935 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369034
EPA review of samples from 125 Cedar; discussion of asbestos and other chemicals.
Similarity score 0.935 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000321265
Jan 12–16 2002 NYC/ER asbestos sampling; Location T access denied; low sample volumes noted.
Similarity score 0.932 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000162494
EPA memo forwarding revised dioxin TEQ analytical results from environmental testing, with three sample reports recalculated per specifications.
Similar indexed content
NYC-WTC_000362551
Discussion of dioxin data, TEQ calculations, and reporting units for comparison to benchmarks.
Similar indexed content
NYC-WTC_000162688
Lab reports corrected dioxin TEQ results from wipe sampling, including non-detect adjustments and analytical methodology documentation pending.
Similar indexed content
NYC-WTC_000162505
Lab correspondence regarding receipt and status of dioxin wipe samples for analysis, with note that PAH wipe extractions were previously disposed of.
Similar indexed content
NYC-WTC_000163072
Review of laboratory data for PAH, lead, and asbestos at 114 Liberty Street noting issues with reporting limits.
Similar indexed content