Page image not rendered yet. The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text
OCR status: ok · source: pdftotext
z z
■<
o DliAFT o
co
§
•2
o
o
Indoor Ambient Air Sampling
“0
C
CT
o'
KJ
"0
CD Agency Date Location N N above N above Comment o
Ca3 Maximum
samples 0.01 OSHA
(fibers/cc) O
fibers/cc * PEL(^ o
o
NYCDEP 9/16 - 9/18 Perimeter of 2 2 0 0.022 PCM Highest Value taken at the 2"‘^ c
Floor of City Hall. No TEM given.. 3
controlled zone (City o
o
Hall)
Neighborhood (400 6 1 0 0.014 PCM Highest value sampled at 400
Chambers St.) Chambers St Lobby. No TEM
given.
Perimeter of 2 2 0 0.044 PCM Highest value sampled at 225
controlled zone (225 Rector Pl Lobby. No TEM given.
Rector Pl)
9/22/01 Inside controlled 4 0 0 0.003 PCM One sample was 0.003 but the other
zone (?) (101 3 were non-detects.
Murray)
* Equivalent to indoor clearance level for residences or schools; NYC-DEP by PCM
@ 0.1 fibers per cc by PCM method; US-OSHA permissible exposure limit for 8 hour time weighted average.
o
H
ro
so
o
1°
o
CD Draft; 9/26/01,7;31 PM '£nvironmentalMonitor!ngUpdate_9_26b[l]
C7C
Page:4 of 6
cn
C7C
ro
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000279371Source: NYC Law Department, mirrored locally
Draft report summarizing air monitoring results at Fresh Kills Landfill showing asbestos fiber concentrations below detection limits in September 2001.