Page image not rendered yet. The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text
OCR status: ok · source: pdftotext
Z z
■<
O DRAFT o
co
§
s
o
o
Ca3
Indoor Ambient Air Sampling
■D
c
CT
o'
Ca3 "0
CD Agency Date Location N N above N above Comment o
CD Maximum
CD samples 0.01 OSHA 03
(fibers/cc) O
fibers/cc * PEL@ o
NYCDEP Perimeter of 2 0 0.022 PCM Highest Value taken at the 2"^ o
9/16 - 9/18 2 c
controlled zone (City Floor of City Hall. No TEM given.. 3
o
3
Hall)
Neighborhood (400 6 1 0 0.014 PCM Highest value sampled at 400
Chambers St.) Chambers St Lobby. No TRM
given.
Perimeter of 2 2 0 0,044 PCM Highest value sampled at 225
controlled zone (225 Rector Pl Lobby. No TEM given.
Rector Pl)
9/22/01 Inside controlled 4 0 0 0.003 PCM One sample was 0.003 but the other
zone (?) (101 3 were non-detects.
Murray)
* Equivalent to indoor clearance level for residences or schools; NYC-DEP by PCM
@0.1 fibers per cc by PCM method; US-OSHA permissible exposure limit for 8 hour time weighted average.
o
n
s
o
o
o
Io
o
Draft: 9/26/01, 11:09 PM \EnvironmentalMonitoringUpdate 9 26b[l]
co
DJ Page: 4 of 6
DJ
(JI
------ - ——c; J - r
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000339994Source: NYC Law Department, mirrored locally
Draft report summarizing air monitoring results at Fresh Kills Landfill showing asbestos fiber concentrations below detection limits in September 2001.