Page image not rendered yet. The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text
OCR status: ok · source: pdftotext
Z
z
DRAFT ■<
o o
s This data was rec’d from DEP today - Ambient air monitoring
co
'2
o
o
Agency Date Location N N above N above Maximum Comment
■D
c
CT
o'
samples 0.01 OSHA (fibers/cc) "0
CD fibers/cc * PEL@ o
Ca3
03
ro NYCDEP 9/15/01- Inside controlled 4 4 0 0.076 PCM Highest value sampled at O
9/16/01 zone Greenwich and Park Place. No o
o
c
TEM given._________________ _ 3
CD
Perimeter of 15 15 0 0.050 PCM Highest value sampled at Murray 3
controlled zone between Church and Broadway.
No TEM given
9/17/01- Perimeter of 10 9 0 0.062 PCM Highest value sampled at Liberty
9/18/01 controlled zone and Barclay. No TEM given
Battery Park City 1 0 0 0.007 PCM Highest value sampled at West
end of Warren St. No TEM
given
9/19/01- Inside controlled 1 1 0 0.012 PCM Highest value sampled at River
9/20/01 zone Terrace and Vesey St. No TEM
given
Perimeter of 4 2 0 0.020 PCM Highest value sampled at Fulton
controlled zone and Church. No TEM given
Battery Park City 11 4 0 0.050 PCM Highest value sampled at North
North End Ave and Park Place west.
No TEM given
Battery Park City 12 4 0 0.050 PCM Highest value sampled at West
South St and Albany. No TEM given
9/20/01- Perimeter of 9 0 0 0.008 PCM Highest value sampled at Fulton
9/21/01 controlled zone and Church. No TEM given
Battery Park City 6 2 0 0.02 PCM Highest value sampled at North
o North End Ave and River Terrace. No
H TEM given
Battery Park City 6 1 0 0.014 PCM Highest value sampled at
South Gateway Plaza and Park. No
O
TEM given
o
o
I
o
o
Oh Draft: 9/26/01, 7:31 PM \EnvironmentalMonitoringUpdate_9_26b[l]
kO Page: 2 of 6
Oh
CB
Oh
co
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000279372Source: NYC Law Department, mirrored locally