Concrete report, WTC paving, Aug 2002

Machine-extracted title · confidence 40%

Concrete test documentation for WTC paving with strength data.

NYC-WTC_000278487
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

MUNICIPAL TESTING LABORATORY, INC. 102 NEW SOUTH ROAD, HICKSVILLE, NEW YORK 11801, 516-938-7120, 516 938-5107 FAX CONCRETE REPORT ^■ent: LIRO Group/NYC DDC Attn; Mike Bailey Report Date: 8/26/02 Address: Six Aerial Way Report Number: DI 018 Lab#: 1404 Syosset, NY 11791 Date Cast: 5/6/02 Project: WTC Paving Project Contractor; Tully/Grace JV Concrete Plant: N/A Strength PSI: 3500 Yards Placed: = FIELD INSPECTION REPORT

Pour Location for Set # 1: Going South on West Broadway, all raised heads, from Franklin St.-South on Broadway Pour Location for Set # 2: Pour Location for Set # 3: Tests made in accordance with ASTM: Yes Not Known Field Inspector (s) ; Client ASTM C 39 COMPRESSIVE STRENGTH TESTS =s=ss =ss3==s==s=s=s=s=s=s=:=s=ss= AREA: 28.27 Cylinder Dia: 6" Cylinder Date Date Slump Air Unit Wt. Temp F. I Truck I Tested Load strength Required Type ID # Cast Tested C143 ;173, C23 C138 C1064 I NO. I Age KN PSI Strength Frac Cylinder Set # 1 6A 5/6/02 5/15/02 3.0 9 822.2 6,540 3,500 A 6B 5/6/02 5/15/02 3.0 9 836.7 6,650 3,500 A 6C 5/6/02 5/15/02 3.0 9 846.5 6,730 3,500 A

Cylinder Set # 2

Cylinder Set # 3

Remarks:

Reviewed By: Laboratory Director Richard Kasparian, P.E conducted tn accordance with ASTM C-39 or AASHTO T-22, By tecfinicians certified by ACI. Municipal Testing is inspected by the Cement and Concrete Reference Laboratory of The National institute of

Su-Mjards and Technology and Is Accredited by: AASHTO and is Licensed by: New York City (#19) and by The State of Florida. 'This report relates only to the item or exact location/ltem tested,

not to the entire construction. It can only be reproduced in tuK. and only wim Municipal Testing taboralory. inc. written permission. Our SaWIrty is strictly limited to the fee paid.

CITY_21MC1OO_OO4662536

NYC-WTC_000278487

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000278487Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →