Concrete field inspection, 6/11/2002

Machine-extracted title · confidence 28%

Field inspection for WTC concrete; S/W/C locations; June 2002.

NYC-WTC_000290445
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

MUNICIPAL TESTING LABORATORY, INC. 102 NEW SOUTH ROAD, HICKSVILLE, NEW YORK 11801, 516-938-7120, 516 938-5107 FAX CONCRETE REPORT Kent: LIRO Group/NYC DDC Attn: Mike Bailey Report Date: 6/11/2002 address; Six Aerial Way Report Number D1110 Lab#; 1402 Syosset, NY 11791 Date Cast; 5/13/2002 Project: WTC Paving Project Contractor; Tully/Grace JV Concrete Plant: N/A Strength PSI: 4000 Yards Placed: FIELD INSPECTION REPORT

Pour Location for Set # 1 : S/W/C, Gold St. & Beekman

Pour Location for Set # 2: Pour Location for Set # 3: Tests made in accordance with ASTM: Yes Not Known Field lnspector(s): Client ASTM C 39 COMPRESSIVE STRENGTH TESTS AREA: 28.27 Cylinder Dia: 6" Cylinder Date Date [Slump Air UnitWt. Temp F. Truck I Tested Load Strength Required Type ID# Cast Tested C143 C173, C231 Cl 38 Cl 064 No. I Age KN PSI Strength Frac Cylinder Set # 1 11A 5/13/2002 5/16/2002 N/A N/A N/A N/A N/A 3 915.9 7,280 4,000 A 11B 5/13/2002 5/20/2002 N/A N/A N/A N/A N/A 7 1009.7 8,030 4,000 A 11C 5/13/2002 6/10/2002 N/A N/A N/A N/A N/A 28 1223.0 9,730 4,000 A

Cylinder Set # 2

Cylinder Set # 3

Remarks:

Reviewed By . Laboratory Director / Richard Kasparian, P.E are conducted in accordance with ASTM C-39 or AASHTO T-22, By technicians certified by ACI. Municipal Testing is inspected by the Cement and Concrete Reference Laboratory of The National Institute of

^l^lards and Technology and is Accrecfitedby: AASHTO and is Licensed by; New York City (#19) and by The State of Florida. This report relates only to the item or exact locationAtem tested,

not to (he entire construction. It can only be reproduced in lull, and only with Municipal Testing Laboratory. Inc. written permission. Our liability is strictly limited to the fee paid.

CITY_21MC100_001659451 NYC-WTC_000290445

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000290445Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →