Concrete field inspection, 6/17/02

Machine-extracted title · confidence 28%

Set 1 and other concrete inspections for WTC project; June 2002.

NYC-WTC_000290446
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

MUNICIPAL TESTING LABORATORY, INC. 102 NEW SOUTH ROAD, HICKSVILLE, NEWYORK11801,516-938-7120, 516 938-5107 FAX CONCRETE REPORT ^KientT" URO Group/NYC DDC Attn: Mike Bailey Report Date: 6/17/2002 Address: Six Aerial Way Report Number Dll 11 Lab#: 1516 Syosset, NY 11791 Date Cast; 5/17/2002 Project; WTC Paving Project Contractor: Tully/Grace JV Concrete Plant; N/A Strength PSI: Yards Placed; 10.1 SSSSSSSSSSSSS^^SE^SSSSSSSSSSSSSSS^SS

FIELD INSPECTION REPORT

Pour Location for Set # 1; on one side of Exchange St. bet. William St. & Hanover St. Pour Location for Set # 2: Pour Location for Set # 3: Tests made in accordance with ASTM: Yes x Not Known Field lnspector(s): Client ASTM C 39 COMPRESSIVE STRENGTH TESTS AREA: 28.27 Cylinder Dia; 6" Cylinder Date Date Slump Air UnitWt. Temp F. Truck Tested Load Strength Required Type ID# Cast Tested C143 C173, C231 C138 C1064 No. Age KN PSI Strength Frac Cylinder Set # 1 Exl 5/17/2002 5/23/2002 4.0 6 368.8 2,930 4, A Ex 2 5/17/2002 6/14/2002 4.0 28 511.9 4,070 4 552 A Ex 3 5/17/2002 6/14/2002 4.0 28 512.8 4,080 4,000 A

Cylinder Set #2

Cylinder Set #3

Remarks:

Reviewed By; Laboratory Director ' Richard Kasparian, P.E tests are conducted in accordance with ASTM 039 or AASHTO T-22. By technicians certified by ACL Municipal Testing is inspected by the Cement and Concrete Reference Laboratory of The National Institute of

^^tandards and Technology and is Accredited by : AASHTO and is Licensed by: New York City (#19) and by The State of Florida. This report relates only to the item or exact location/item tested.

not to the entire construction, it can only be reproduced in full, and only with Municipal Testing Laboratory, Inc. written permission. Our liability is strictly limited to the fee paid.

CITY_2IMCl0 0_0 01659452 NYC-WTC_000290446

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000290446Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →