Lab report: PCM fiber results, 8-0^-^717

Machine-extracted title · confidence 20%

PCM fiber results for multiple samples with fiber counts.

NYC-WTC_000278031
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

z sJI .Jr 8-0^-^717 ( z ( § Client Name; Applied Technology Services, Inc. o o o Phase Contrast Microscopy (PCM) Fiber Results - o A98113; Fittennan Hall "0 KJ c CT OO O Flow Air Fiber Fibers o’ O SciLab Client Date Rate Duration Filtered Density Cone. ■0 Fields Fibers TWA o Sample # Sample # / Location Collected (Hters/min.) (min.) (liters) (Fibers/mm ) (Fibers/cc) a. 9L 01 YR-090998-09 9/9l9i 5 150 750 100 12 15.29 0.008 O o o Northwest Comer 13th Fl. by Tent c 3 02 YR-090998-10 9/9/98 5 150 750 100 16 20.38 0.010 CD 3 North Wall 13th FI. by Tent 03 YR-090998-11 9/9/98 5 150 750 100 4 5.10 < 0.004 Middle North Wall 13th FI. by Tent 04 YR-090998-12 9/9/98 5 150 750 100 2 2.55 < 0.004 Northeast Comer 13th Fl. by Tent 05 YR-090998-13 9/9/98 5 150 750 100 3 3.82 < 0.004 By Elevator 13th Fl. 06 YR-090998-14 9/9/98 0 0 0 100 0.5 0.64 Field Blank Footnotes: / 07 YR-090998-15 9/9/98 0 0 0 100 0.5 0.64 Field Blank Footnotes: I Reporting Notes: (1) Fibers/cc cannot be calculated for samples (or blanks) with no air volume. Analyzed by; Larisa Srybnaya ; Date Analyzed: 9/10/98 Samples analyzed by NIOSH 7400(A) METHOD, Isstie #2, 8/15/94; Limit of Detection = 5.5 fibers per 100 fields or 7 fibers / mm2; This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area; ND = no fibers observed; NA = Not Analyzed; Walton - Beckett gradicule field area 0.00785 mm2; Duration in minutes; TWA = 8Hr TWA calculation assumes zero exposure for remainder of 8 hour period not sampled; Upper 95% Confidence Limit (Employer's Compliance Test) - Calculated as a one sided UCL to determine 95% certainty of compliance with the 0.01 fiber/cc standard; Estimated relative standard deviation: Intralab St = 0.270, Interlab Sr = 0.450. ELAP #11480

o H

KJ

I o o I o Co

o

Co

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000278031Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →