Air Sampling Report, Fiterman Hall, CUNY

Machine-extracted title · confidence 54%

Air sampling report for Security Booths at CUNY Fiterman Hall, Mar 14, 2002.

NYC-WTC_000277931–000277934
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

2

3b#; 202022493 f of 1 Z

I o co Client Name: Applied Technology Services, Inc. o o Phase Contrast Microscopy (PCM) Fiber Results ■D o c CT E02403; Fitterman Hall o' co o Flow Air Fiber Fibers "□ o -PS. SciLab Client Rate Duration Filtered Density Cone. Fields Fibers TWA Q3 Sample # Sample # / T.ocation Collected (liter'/tnln ' t'mia.i (liters) (Fibers/mm ) (Fibers/cc) O o 01 45-2-15-02-01 2/15/02 10 95 950 100 2 2.55 < 0.003 o c BKG-Gtound Floor, By Secuirty Booth Comer of Park Place and Greenwich Street 3 Q 3 02 45-2-15-02-02 2/15/02 4 245 980 100 6 7.64 0.003 BKG-Ground Floor, By Security Booth of Barclay Street and West Broadway 03 45-2-15-02-03 2/15/02 0 0 0 100 0.5 0.64 Field Blank Footnotes: I Reporting Notes: (1) Fibers/cc cannot be cglcuW^ with no air volume. Analyzed by: Anthony Hinton/^^^Sj^ : Dale Analyzed: 2/15/02 Samples analyzed by NIOSH 7400(A) M^odJ Issue #2, 8/15/94: Limit of Detection= 5.5 fibers per 100 fields or 7 fibers/mm2: This report relates ONLY to Ilie sample analysis expressed as fibers/sq mm of filler area ND=Ng fibers observed; NA= Not Analyzed; Walton-Beckett graticle field ar5T= 0.00785 mm2: TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled: Upper 95% Confidence limit (Employers Compliance Testi- Calculated as a one sided I 'CL to determine 95% certainty of compliance with the O.Ol fiber/cc standard: Estimated relative standard deviation; Intralab Sr=0.405, Inlerlab Sr=0.45. New York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technolopy Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. AIBA # 102843.

o H K I

S o o o I o

co CD

Cn

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000277934Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →