Lab report: PCM fiber results, Final: 14th Flr

Machine-extracted title · confidence 20%

Phase/contract/di assessment data and PCM fiber results for 14th Floor.

NYC-WTC_000278028–000278029
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

2 sj l)7 r. < ( Z ■<

§ Client Name: Applied Technology Services, Inc. o co CD O Phase Contrast Microscopy (PCM) Fiber Results CD KJ A98113; 14thFlr./Finals “D c 00 CT O KJ Flow Air Fiber Fibers o' CO SciLab Client Date Rate Duration Filtered Density Cone. tvVA "0 Fields Fibers o Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm ) (Fibers/cc) 9L 16 34090998-23 9/9/98 15 210 3150 100 1 1.27 < 0.001 O o o 14th Fir.. Fin-Tent #9 c 3 Reporting Notes: CD 3 (1) Fibers/cc cannot be calculated for^m^s (or blanks) with no air volume. Analyzed by: Fred Corirossi J~-C ..; Date Analyzed: 9/10/98 Samples analyzed by NIOSH 7400(A) METHOD, Issue #2, 8/15/94; Limit of Detection = 5.5 fibers per 100 fields or 7 fibers / mm2; This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area; ND = no fibers observed; NA = Not Analyzed; Walton - Beckett gradicule field area 0.00785 mm2; Duration in minutes; TWA = 8Hr TWA calculation assumes zero exposure for remainder of 8 hour period not sampled; Upper 95% Confidence Limit (Employer’s Compliance Test) - Calculated as a one sided UCL to determine 95% certainty of compliance with the 0.01 fiber/cc standard; Estimated relative standard deviation: Intralab Sr = 0.270, Interlab Sr = 0.450. ELAP #11480

o H

I o r o o

o

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000278029Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →