Post 2'“' Cleaning Samples - There were two post second cleaning air samples collected. The air samples were analyzed using TEM AHERA, and TEM PCMe. The samples could not be analyzed for PCM, due to overloading of particulate matter on the filters. The TEM AHERA results were below the secondary numeric criterion of 0.022 S/cc, with the samples being below the detection limit. Similarly, the TEM PCMe results were below the primary numeric criteria of 0.0009 S/cc with the samples likewise being below the detection limit.

Dioxin Before Cleaning Samples - There were no before cleaning samples collected.

Post J" Cleaning Samples - There were no post-first cleaning samples collected.

Post 2”'^ Cleaning Samples - There were no post-second cleaning samples collected.

Gypsum Before Cleaning Samples - There were no before cleaning samples collected.

Post P' Cleaning Samples - There was one air sample collected after the first cleaning. The result indicates that gypsum was not detected in the sample. Since gypsum was below the detection for the sample collected, there were no additional gypsum samples collected.

Lead Before Cleaning Samples - There were no before cleaning samples collected.

Post P' Cleaning Samples - There was one air sample collected after the first cleaning, and the air sample was below the numeric criterion of 1 p,g/m\ Since the numeric criterion was met for lead after the first cleaning, no additional lead samples were collected.

Alpha-Quartz Before Cleaning Samples - There were no before cleaning samples collected.

Post P' Cleaning Samples - There was one air sample collected after the first cleaning. The sample was below the detection limit. Since the sample was below the detection limit after the first cleaning, no additional samples were collected for alpha­ quartz.

Calcite Before Cleaning Samples - There were no before cleaning samples collected.

83

CITY_21MC100_004205039

NYC-WTC_000276735

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276735Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000243565

EIA report for Law Department project at 100 Church Street by TRC.

Similar indexed content

Compare copies and versions →