INTERNAL REVIEW DRAFT

Post J" Cleaning Samples - There were three air samples and five wipe samples collected after the first cleaning. All of the air sample results indicate that MMVF was present but at levels below the numeric criterion of 10 S/L. All of the wipe sample results were in the range of 114.46 S/L to 228.93 S/L. This indicates that the cleaning method was able to reduce the pre-cleaning concentration of MMVF.

PAHs Before Cleaning Samples - There were four pre-cleaning wipe samples collected. All four samples were below the detection limit, and the TEF of 300 qg/mf

Post P' Cleaning Samples - There were four post-cleaning wipe samples collected. All four samples were below the detection limit and the TEF value was below the primary numeric criterion of 300 pg/m\

Total Dust Before Cleaning Samples - There were four pre-cleaning wipe samples collected; however, EPA only requested to have one of the samples analyzed. The results indicate that dust was present.

Post Cleaning Samples - There were four post-cleaning wipe samples collected; however, EPA only requested to have two of the samples analyzed. The analyzed samples indicate that dust was present at concentrations slightly lower than the pre­ cleaning concentrations.

Fifth Floor Hallway - The fifth floor hallway is an area with plywood floors and walls made of sheet rock covered with wallpaper glue. The ceiling is also made of sheet rock, and is painted.

Cleaning method - This area was cleaned twice using test method 4A and test method 4B. Test method 4A used an industrial HEPA filtered vacuum and an AFD, while test method 4B consisted of a soap and water wet wipe of only the ceiling.

Numeric Criteria - This unit met the numeric criteria listed in Table 1 for each compound after being cleaned once.

Asbestos Before Cleaning Samples - There were no before cleaning samples collected.

Post P' Cleaning Samples - There were two post first cleaning air samples collected. The air samples were analyzed using PCM. The PCM results were below the secondary numeric criterion of 0.01 f/cc. The samples could not be analyzed for TEM PCMe, due to overloading of particulate matter on the filters. ■*

82

CITY_21MC100_004205038

NYC-WTC_000276734

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276734Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000243565

EIA report for Law Department project at 100 Church Street by TRC.

Similar indexed content

Compare copies and versions →