Post J" Cleaning Samples - There were three air samples and five wipe samples
collected after the first cleaning. All of the air sample results indicate that MMVF
was present but at levels below the numeric criterion of 10 S/L. All of the wipe
sample results were in the range of 114.46 S/L to 228.93 S/L. This indicates that the
cleaning method was able to reduce the pre-cleaning concentration of MMVF.
PAHs
Before Cleaning Samples - There were four pre-cleaning wipe samples collected. All
four samples were below the detection limit, and the TEF of 300 qg/mf
Post P' Cleaning Samples - There were four post-cleaning wipe samples collected.
All four samples were below the detection limit and the TEF value was below the
primary numeric criterion of 300 pg/m\
Total Dust
Before Cleaning Samples - There were four pre-cleaning wipe samples collected;
however, EPA only requested to have one of the samples analyzed. The results
indicate that dust was present.
Post Cleaning Samples - There were four post-cleaning wipe samples collected;
however, EPA only requested to have two of the samples analyzed. The analyzed
samples indicate that dust was present at concentrations slightly lower than the pre
cleaning concentrations.
Fifth Floor Hallway - The fifth floor hallway is an area with plywood floors and walls made
of sheet rock covered with wallpaper glue. The ceiling is also made of sheet rock, and is
painted.
Cleaning method - This area was cleaned twice using test method 4A and test method
4B. Test method 4A used an industrial HEPA filtered vacuum and an AFD, while
test method 4B consisted of a soap and water wet wipe of only the ceiling.
Numeric Criteria - This unit met the numeric criteria listed in Table 1 for each
compound after being cleaned once.
Asbestos
Before Cleaning Samples - There were no before cleaning samples collected.
Post P' Cleaning Samples - There were two post first cleaning air samples collected.
The air samples were analyzed using PCM. The PCM results were below the
secondary numeric criterion of 0.01 f/cc. The samples could not be analyzed for TEM
PCMe, due to overloading of particulate matter on the filters.
■*