Asbestos
Before Cleaning Samples - Pre-cleaning air, micro vacuum and wipe samples were collected
for asbestos. These samples indicate that asbestos was present in the unit prior to cleaning.
The two air samples that were collected were analyzed using PCM and TEM PCMe. The
PCM results were both below the secondary numeric criterion of 0.01 f/cc. The PCMe
results indicate that both samples were below the detection limit and below the numeric
criterion of 0.0009 s/cc. Two of the three micro vacuum samples detected chrysotile and the
third sample was below the detection limit. Three of the four wipe samples were below the
detection limit and the fourth one detected chrysotile at a concentration slightly above the
detection limit.
Post J" Cleaning - There were post-cleaning air, micro vacuum, and wipe samples collected.
Fourteen air samples were collected after the first cleaning event. Each of these samples
were analyzed using PCM, TEM AHERA, and TEM PCMe; however, eleven of the samples
(i.e., 9094-A-3B-026 thru 9094-A-3B-036) were collected to evaluate problems associated
with particulate overloading of the filters. These eleven samples were collected using various
flow rates. The results from ten samples collected to evaluate filter overloading indicate that
there was one PCM result that exceeded the secondary numeric criterion of 0.01 f/cc and that
there were four TEM PCMe results that exceeded the primary numeric criterion of 0.0009
S/cc. The remaining results for these samples indicate that the PCM, TEM AHERA, and
TEM PCMe values were either at or below any associated secondary or primary numeric
criterion.
The three samples that were collected to evaluate if additional cleaning events were necessary
indicate that all three PCM results were below the secondary numeric criterion of 0.01 f/cc
and that the TEM AHERA and TEM PCMe analyses could not be conducted due to
overloading of particulate material. Due to not having valid TEM PCMe results, a second
cleaning was conducted.
The results for the three micro vacuum samples indicate that asbestos was present at levels
similar to those observed before cleaning.
The results for the five wipe samples that were collected indicate that asbestos was present in
all five of the samples at slightly higher concentrations than the pre-cleaning samples. One of
the five samples in which asbestos was detected was below the detection limit.
Post 2'“^ Cleaning - There were three asbestos air samples collected after the second cleaning.
The samples were analyzed for PCM, TEM AHERA, and TEM PCMe. Two of the three
PCM results were below the detection limit and all three below the secondary numeric
criterion of 0.01 f/cc. All three TEM AHERA results were below the detection limit and also
were below the secondary numeric criterion of 0.022 s/cc. All three TEM PCMe results were
below the detection limit and below the primary numeric criteria of 0.0009 s/cc. All of the