NYC-WTC_000363060
Interim final report noting organizations involved and plan for third-party review.
44 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗EPA NYC Region 2 WTC response document, City data file.
NYC-WTC_000431857–000432027OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Unit 3B - This unit is located on the third floor. It is a 968 sq. ft. loft with three bedrooms facing Cedar Street. The unit has hardwood floors. No windows were blown in and the unit presented minimal dust accumulation, with the exception of the baseboard heating units, which contained visible dust. All of the tenant’s personal items remained in the unit and were cleaned.
Cleaning Method - This unit was cleaned using the Scope A cleaning procedures: industrial HEPA-filtered vacuum of all surfaces. An AED was used. All surfaces were wet wiped. This cleaning method was used for each cleaning event in this unit.
Cleaning Results - This unit met the primary clearance criteria listed in Table 1.0 for each compound after being cleaned twice.
Asbestos Before Cleaning Samples - Two air, three micro vacuum and four wipe samples were collected for asbestos. These samples indicate that asbestos was present in the unit prior to cleaning. The two air samples that were collected were analyzed using PCM and PCMe. One PCM result was below the secondary numeric criterion of 0.01 f/cc. The other PCM result was above the secondary numeric criterion. The PCMe results indicate that both samples were below the detection limit and below the primary clearance criterion of 0.0009 S/cc. Two of the three micro vacuum samples detected chrysotile. The third sample was below the detection limit. Three of the four wipe samples were below the detection limit. The fourth one detected chrysotile at a concentration slightly above the detection limit.
Post P‘ Cleaning - Three air, three micro vacuum and five wipe samples were collected to evaluate if additional cleaning events were necessary. The three air samples that were collected indicated that all three PCM results were below the secondary numeric criterion of 0.01 f/cc and that the TEM AHERA and PCMe analyses could not be conducted due to overloading of particulate material. Due to inconclusive PCMe results, a second cleaning was conducted.
The results for the three micro vacuum samples indicate that asbestos was present at levels similar to those observed before cleaning.
The results for the five wipe samples that were collected indicate that asbestos was present in all five of the samples at slightly higher concentrations than the pre-cleaning samples. One of the five samples in which asbestos was detected was below the detection limit. Post 2’^ Cleaning - Three asbestos air samples were collected after the second cleaning. The samples were analyzed for PCM, TEM AHERA, and PCMe. Two of the three PCM results were below the detection limit; all three were below the secondary numeric criterion of 0.01 f/cc. All three TEM AHERA results were below the detection limit and below the secondary numeric criterion of 0.022 S/cc. All three PCMe results were below the detection limit and below the primary clearance criterion of 0.0009 S/cc. All of the air asbestos results after the second cleaning were at lower concentrations than the pre cleaning samples and the samples collected after the first cleaning. This indicates that the cleaning techniques used were efficient at removing asbestos to levels that were below
48
CITY_21MC100_011132927
NYC-WTC_000431908
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000363060
Interim final report noting organizations involved and plan for third-party review.
44 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000195194
Document excerpt acknowledging contributors and outlining the collaborative scope of an EPA environmental protection study regarding the World Trade Center site.
45 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145695
Form documenting the tracking and handling of environmental samples collected by the Department of Environmental Protection.
45 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000276652
Table of contents for contaminants of [name] report and building sections.
32 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145027
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
28 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155174
Chain of custody documentation for cleanup and monitoring samples at 114 Liberty distributed among project team members.
12 shared non-person entities · 1 shared topics · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162938
Correspondence regarding monitoring activities and documentation for the asbestos cleanup at 114 Liberty Street in early 2003.
12 shared non-person entities · 1 shared topics · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000138897
Internal DEP coordination regarding comments on 114 Liberty procedures and preparation of a response.
12 shared non-person entities · 1 shared topics · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243565
EIA report for Law Department project at 100 Church Street by TRC.
17 shared non-person entities · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243703
Environmental assessment prepared for NYC Law Department by TRC Engineers, April 8, 2002.
17 shared non-person entities · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155286
Formal letter criticizing the EPA and DEP for alleged failures in cleaning asbestos and silica from 114 Liberty Street.
13 shared non-person entities · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000176247
Comprehensive environmental assessment report prepared by TRC Engineers for the New York City Law Department.
17 shared non-person entities · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000195194
Document excerpt acknowledging contributors and outlining the collaborative scope of an EPA environmental protection study regarding the World Trade Center site.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145695
Form documenting the tracking and handling of environmental samples collected by the Department of Environmental Protection.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000363060
Interim final report noting organizations involved and plan for third-party review.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000195194
Document excerpt acknowledging contributors and outlining the collaborative scope of an EPA environmental protection study regarding the World Trade Center site.
Similarity score 0.985 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000363060
Interim final report noting organizations involved and plan for third-party review.
Similarity score 0.984 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145695
Form documenting the tracking and handling of environmental samples collected by the Department of Environmental Protection.
Similarity score 0.984 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000195194
Document excerpt acknowledging contributors and outlining the collaborative scope of an EPA environmental protection study regarding the World Trade Center site.
Similar indexed content
NYC-WTC_000363060
Interim final report noting organizations involved and plan for third-party review.
Similar indexed content
NYC-WTC_000145695
Form documenting the tracking and handling of environmental samples collected by the Department of Environmental Protection.
Similar indexed content
NYC-WTC_000276652
Table of contents for contaminants of [name] report and building sections.
Similar indexed content
NYC-WTC_000145027
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
Similar indexed content