3.B. Pre-Cleanup Sampling
Prior to cleanup activities, wipe samples were collected from each of the thirteen residential units
and the two commercial units included in the Study (Chiropractor’s Office, Mattress Retail Store).
The wipe samples were collected from a 10 cm x 10 cm area using dedicated, disposable templates
which were left in-place. One sample was collected from the surface of each of the following four
non-porous locations within each unit: ceiling, wall, bare floor, and a horizontal surface (ie. counters,
tables, dressers, window sills). All samples were analyzed for asbestos, MMVF, lead, PAHs,
dioxins/furans, and silica. Exceptions to this were the ceiling samples which were analyzed for
asbestos only, and horizontal surfaces which were also analyzed for total dust. Generally, air
sampling pre-cleaning was not conducted because of concerns that the presence of significant levels
of dust accumulation might make overloading the filters more likely using the aggressive technique.
Pre-cleanup sampling also included the collection of micro vacuum samples from up to six porous
surface areas (ie. carpets, furniture fabric) in eleven of the thirteen residential units, and both
commercial units included in the Study (ie. Retail Mattress Store, Chiropractor’s Office. The wipe
samples were collected from a 10 cm x 10 cm area using dedicated, disposable templates which were
left in place. Each unit contained a different number of porous surface sample areas, except Unit 4B
which did not have any porous surfaces from which to collect a sample. The micro vacuum samples
were analyzed for lead and for asbestos (TEM).
3,C. Sampling During Cleanup
All sampling conducted during cleaning activities was undertaken for the purpose of documenting
potential worker exposure to asbestos, lead and silica. Samples were collected from the breathing
zone (5-6 ft.) in the center of the room being cleaned. The pumps were run the entire length of the
work day (8 hour minimum) and were not stopped during breaks. Notably, at no time during the
Study were any cleanup workers exposed to any contaminants above the regulatory standards for
permissible exposure levels. (Attachment 2, Personal Monitoring Data)
3.D. Post-Cleanup Sampling
Post-cleaning sampling conducted was designed to detemiine if the cleaning methods attained the
health-based benchmarks established in EPA's draft report "World Trade Center Indoor Air
Assessment; Selecting Contaminants of Concern and Setting Health-Based Benchmarks".
Following cleanup activities in the twelve residential and three commercial Units, post-cleanup wipe
and micro vacuum samples were collected in the same manner as the pre-cleanup samples. The
post-cleanup samples were collected adjacent to the pre-cleanup sampling locations whenever
possible. In situations where the pre-cleanup sampling location was now inaccessible, a new sample
location was collected as close to the initial location as possible. Post-cleanup area air samples were
collected in each of the thirteen residential units and each of the two commercial units included in
the Study. The analyses for these samples included MMVF, silica, lead, and asbestos via the TEM
and Phase Contrast Microscopy (PCM) methods. The building's four hallways, two stairwells.
25