Liberty St. Industrial HEPA vacuum. Test 4A,4B Horizontal & Venical soap/water Silica (Air) exceedance
Stairwell w/AFD Surfaces
2.K. Difficulties Encountered and Resolutions
A summary of the difficulties encountered during the cleaning operations and how they were
resolved is included in Attachment 13.
SECTION 3 - SUMMARY OF SAMPLING ACTIVITIES
3.A. Baseline Sampling o
Prior to initiating cleanup activities, bulk composite samples were collected in each of the three units
which had sufficient dust present to collect a bulk sample. These Units included 5C, and the two
commercial Units on the 2nd floor (Retail Mattress Store, Chiropractor’s Office). The bulk samples
were analyzed for silica, manmade vitreous fibers (MMVF), lead, polynuclear aromatic
hydrocarbons (PAHs), dioxins/furans, and asbestos via the Polarized Light Microscopy (PLM) and
Transmission Electron Microscopy (TEM) methods. However, due to insufficient volume, the
sample collected from Unit 5C was not analyzed for PAHs or dioxins/furans.
EPA's evaluation of the analytical data from the bulk composite sampling event was utilized in
identifying COPC concentrations present in the settled dust, and assisted EPA in determining the
applicability of regulatory standards and in identifying potential health and safety concerns. Data
results of the bulk sampling are not included in this report. EPA will provide this upon request.
In addition to the collection of bulk composite samples, baseline air samples were also collected.
These samples were collected from the breathing level (5-6 ft.) from the main living area of the units
which, based upon visual observations, were the least and most impacted by the WTC disaster.
Samples collected from the least impacted Units (3A and 3B) represented a best case test and were
analyzed for asbestos and MMVF. Samples collected from the most impacted areas (Retail Mattress
Store, Chiropractor’s Office) represented a worst case test and were analyzed for dioxin/furans,
PAHs, asbestos and MMVF.
EPA's evaluation of the baseline air sampling event determined that the airborne concentrations of
PAHs and dioxin/furans were not a health concern; and thus, the collection of additional air samples
for these parameters would not be necessary. This decision was based on the analysis of baseline
PAHs and dioxin/furan air samples co-located and collected from the most impacted units from
which bulk samples were also collected and analyzed for PAH and dioxin/furans. As the air samples
did not contain PAHs or dioxin/furans at concentrations above EPA's stringent Tier III clearance
criteria, EPA determined that airborne PAHs or dioxin/furans would also not be present in the other
less impacted units. EPA's decision to eliminate PAHs and dioxin/furan analyses for air sample was
later checked through the collection of a reference samples in Unit 4C. This sample was analyzed
for PAHs and the analytical result was found to be below the numeric criteria of 0.2 ug/m3.
24