NYC 9/11 Public Portal Document
3. Sampling Activities
3.1 Baseline Sampling
Prior to initiating cleanup activities, bulk composite samples were collected in each of the three
units which had sufficient dust present to collect a bulk sample. These Units included 5C, and the
two commercial units on the second floor (Mattress Store, Chiropractor’s Office). The bulk
samples were analyzed for alpha-quartz, MMVF, lead, PAH, dioxins/furans, and asbestos. Due to
insufficient volume, the sample collected from Unit 5C was not analyzed for PAH or
dioxins/furans.
EPA's evaluation of the analytical data from the bulk composite sampling event was utilized in
identifying COPC concentrations present in the settled dust, and assisted EPA in determining the
applicability of regulatory standards and in identifying potential health and safety concerns.
Analytical results of the bulk sampling are not included in this report.
In addition to the collection of bulk composite samples, baseline air samples were also collected.
These samples were collected from the breathing level (5-6 ft.) and from the main living area of
the units which, based upon visual observations, were both the least and the most impacted by the
WTC disaster. Samples collected from the least impacted apartments (Units 3 A and 3B)
represented a best case test and were analyzed for asbestos and MMVF. Samples collected from
the most impacted areas (Mattress Store, Chiropractor’s Office) represented a worst case test and
were analyzed for dioxin/furans, PAH, asbestos and MMVF.
EPA's evaluation of the baseline air sampling event determined that the airborne concentrations of
PAH and dioxin/furans were not a health concern; therefore, the collection of additional air
samples of these parameters was not necessary. This decision was based on the analysis of
baseline bulk and air PAH and dioxin/furan samples which were collected from the most severely
impacted units. As the air samples did not contain PAH or dioxin/furans at concentrations above
the stringent primary clearance criterion as established in the COPC/Benchmarks Report", EPA
determined that airborne PAH or dioxin/furans would also not be present in the other less
impacted units. EPA's decision to eliminate PAH and dioxin/furan analyses for air samples was
later confirmed through the collection of reference samples in Unit 4C. These samples were
analyzed for PAH and the analytical result was found to be below the clearance criterion of 0.2
pg/m’.
3.2 Pre-Cleaning Sampling
Prior to cleaning activities, wipe samples were collected from each of the thirteen residential units
and the two commercial units included in the study (Chiropractor’s OflBce, Mattress Store). The
wipe samples were collected from a 10 cm x 10 cm area using dedicated, disposable templates
which were left in-place. One sample was collected from the surface of each of the following four
non-porous locations within each unit: ceiling, wall, bare floor, and horizontal surface (e.g.,
counters, tables, dressers, window sills). All samples were analyzed for asbestos, MMVF, lead,
PAH, dioxins/furans, and alpha-quartz. Exceptions to this were the ceiling samples which were
"U.S. Environmental Protection Agency. (September, 2002). World Trade Center Indoor Air
Assessment: Selecting Contaminants of Concern and Setting Health-Based Benchmarks.
27
NYC-WTC_000145725
OCR can misread numbers and units. Confirm readings against the page image before using them.