NYC 9/11 Public Portal Document
INTERNAL REVIEW DRAFT
Summary of Conclusions Based on the Data from Residential Unit Cleanings:
Various levels of contamination associated with the WTC disaster were detected in
the building; some levels exceeded health based benchmarks.
• Of the twenty-five sites inside the building (13 residential units, 5 commercial
units, and 7 building interior or common areas), nineteen sites (76%) had
exceedances of health-based benchmarks for one or more contaminants
associated with the WTC collapse. The nineteen sites include all residential
and commercial units and one stairwell area.
• The Table of Exceedances (Table 9. Contaminants of Potential Concern
Exceedances by Event) and the Section 4 - Discussion of Results provide the
specific details on these exceedances.
Visual observations of dust generally corresponded with levels of contamination
found in the dust.
• The units identified as having a significant amount of dust pre-cleaning also
ranked highest in a comparison of levels of contamination found in the dust.
Five of the six units (Units 3C, 3D, 4C, 4D, 5C) with significant amounts of
observable dust were in the top half of the rankings of average contamination
of units.
• The windows from units listed above were blown-in during the collapse of the
WTC.
• Table 8, Ranking of Residential Units by Pre-Cleaning Average
Concentrations of Several Contaminants illustrates this finding.
Generally units facing ground zero corresponded with higher average level of
contamination within the unit for lead, asbestos. MMVF pre- and post-cleaning
sampling.
• Units facing Liberty Street C and D units) which were in the direct path of the
WTC collapse generally showed the greatest degree of contamination.
• Table 8, Ranking of Residential Units by Pre-Cleaning Average
Concentrations of Several Contaminants illustrates this finding.
• The derivations of each unit’s ranking for the sum of ranks are tabulated in
Table 10, Each Residential Unit is Assigned a Rank for each of Four
Contaminant/Sample Types Based on the Average Level of Contamination
Before Cleaning.
The evaluation of the various cleaning techniques did not identify one cleaning
method that was clearly superior to the others.
• Results suggested that there was no substantial difference in the cleaning
effectiveness between basic and advanced cleaning methods.
• Four units (1 A, 3A, 2B, 3B) met the numeric criteria after the first cleaning.
These units were in the lower half of the units in terms of average levels of
114
CITY_21MC100_004205070
NYC-WTC_000276766
OCR can misread numbers and units. Confirm readings against the page image before using them.