wipe sampling, lead wipe and micro vacuum sampling and MMVF wipe sampling.
However, there was not any lead micro vacuum sampling in unit 4B because of the
absence of porous surfaces thereby limiting the usefulness of the data from this unit
for comparison to others in overall average levels of contamination.
Asbestos micro vacuum data were not included for interpretative purposes because
the results were extremely vai’iable and did not present consistent trends, as did other
data. The Indoor Air Workgroup debated the inclusion of asbestos micro vacuuming
in this study and had concerns that the results would not be relevant because as stated
in the ASTM - Standard Test Method for Micro vacuum Sampling and Indirect
Analysis of Dust by Transmission Electron Microscopy for Asbestos Structure
Number Concentrations “...the collection efficiency of this technique is unknown and
will vary among substrates.” The high degree of uncertainty in predicting airborne
asbestos levels based on the amount in settled dust was recently reiterated by a panel
of experts that peer reviewed an EPA report that proposed a health-based benchmark
for asbestos in settled dust based utilizing a K factor approach. Specifically the peer
review panel (www.tera.org) stated; "The panel did not endorse the asbestos settled
dust benchmark because the only relevant exposure pathway for asbestos is inhalation
and the K-factor methodology is, at this time, inadequate for predicting inhalation
exposure from asbestos surface loading measurements." Although the method was
included, the results appear to confirm the uncertainty with quantifying asbestos by
this technique.
As the pre-cleaning wipe samples presented the most complete data set for asbestos,
lead, and man-made vitreous fibers (MMVF), as well as the micro vacuum samples
for lead, these four data sets were used to determine if the residential units had similar
levels of contamination prior to cleaning. The results for each compound and sample
type were averaged by unit and then ranked from the highest concentration to the
lowest concentration, which resulted in each unit having four rankings (i.e., one for
each compound and/or sample type). The range of the highest concentration to the
lowest concentration for each compound or sample type spanned an order of
magnitude. Once the units were assigned a ranking for each compound or sample
type (Table 8), the rankings for each unit were summed to create a variable called
"sum of ranks" (Table 8). The sum of ranks has a theoretical range of four to forty
eight, while the observed range in this evaluation was thirteen to forty-five. This
indicates that there was some variability between units in regards to the highest
concentrations for each compound and less variability with regard to the lowest
concentrations for each compound. The results of the ranking evaluation indicates
that there was a difference in the degree of contamination between units prior to the
cleaning events.