NYC 9/11 Public Portal Document
apartment were recorded in the initial phase of the study, prior to cleaning. Six apartments were
identified as having accumulated a significant amount of dust. The remaining seven apartments
were identified as having a minimal amount of dust accumulation. All of the apartments
characterized as containing a significant amount of dust presented windows that had been blown
in during the collapse of the WTC. The visual observations were used in an attempt to distribute
the cleaning methods evenly, based on the amount of dust present.
Once the analytical results were available, it was possible to quantitatively determine differences
that existed in the amount of contamination that was present in the apartments prior to cleaning.
As indicated above, the pre-cleaning results for asbestos wipe sampling, lead wipe and micro
vacuum sampling, and MMVF wipe sampling results from the residential units provided the most
complete data set for determining the existing contamination in apartments prior to cleaning.
These four data sets were used to establish differences in contamination between apartments prior
to cleaning.
The results for each data set identified above were averaged by unit, then ranked from the highest
concentration t the lowest concentration, which resulted in each unit having four rankings (one for
each data set). These rankings are presented in Table 9.0.
The range of the highest concentration to the lowest concentration for each compound or sample
type spanned an order of magnitude. One apartment, 4B, did not contain any porous surfaces that
could be sampled, therefore there were no micro vacuum samples collected. This prohibited this
unit from being included in the ranking.
Once the units were assigned a ranking for each data set, the rankings for each unit were summed
to create a variable called "sum of ranks". This information is presented in Table 10.0. The sum
of ranks has a theoretical range of 4-48, while the observed range in this evaluation was 13-45.
This indicates that there was generally an even distribution within the theoretical range, with the
exception of the lower end of the range, as there were no units which ranked less than 13.
Therefore, the visual observations of dust generally corresponded with levels of contamination
found in the dust. The results of the ranking evaluation indicates that there was a difference in the
degree of an average contamination for these compounds between units prior to the cleaning
events.
105
NYC-WTC_000145803
OCR can misread numbers and units. Confirm readings against the page image before using them.