PCMe. The PCM results indicate that all three samples were below the detection
limit and below the secondary numeric criterion of 0.01 f/cc. The TEM AHERA
results indicate that all three samples were below the detection limit and below the
secondary numeric criterion of 0.022 S/cc. The TEM PCMe results indicate that all
three samples were below the detection limit and below the primary numeric criterion
of 0.0009 S/cc.
Dioxin
Before Cleaning Samples - There were pre-cleaning wipe and air samples collected
and analyzed for dioxin. The results indicate that there was dioxin present; however,
the TEQ concentration for each sample was below the numeric criterion of 0.001
ng/m^ for air and 4 ng/m^ for settled dust.
Post P' Cleaning Samples, Test 4A - There were four post-cleaning wipe samples
collected and analyzed for dioxin. The results indicate that the concentrations of
dioxin detected were similar to the pre-cleaning samples and the TEQ concentration
for each sample was below the criterion of 4 ng/m\
Post P' Cleaning Samples, Test 4B - There were four post-cleaning wipe samples
collected and analyzed for dioxin. The results indicate that the concentrations of
dioxin were slightly higher than the pre-cleaning samples and the TEQ concentration
for each sample was below the criterion of 4 ng/m^
Post E' Cleaning Samples, Test 4E - There were two post-cleaning wipe samples and
two pre-water wipe samples collected and analyzed for dioxin. The results indicate
that the concentrations of dioxin were similar to the pre-cleaning samples and all TEQ
concentration was below the criterion of 4 ng/m^.
Gypsum
Before Cleaning Samples - There were four pre-cleaning wipe samples collected. The
results indicate gypsum was not detected above the detection limit of 40 mg/m^.
Post P' Cleaning Samples, Test 4A - There were two air and four wipe samples
collected. Sampling results indicate that gypsum was not detected in air above the
detection limit or in wipe samples above the detection limit. One of the four wipe
samples was broken in transit and could not be analyzed.
Post Cleaning Samples, Test 4B - There were two air and four wipe samples
collected. Sampling results indicate that gypsum was not detected in air above the
detection limit. Two of the four wipe samples were below the detection limit. The
other two wipe samples concentrations were detected at 158 mg/nV and 383 mg/m^.