NYC 9/11 Public Portal Document
INTERNAL REVIEW DRAFT
Post J" Cleaning Samples, Test 4C - There were two air samples collected. Sampling
results indicate that gypsum was not detected in air above the detection limit.
Lead
Before Cleaning Samples - There were seven micro vacuum samples and three wipe
samples collected. All seven micro vacuum samples were below the comparison
value of 25 pgriL. Two of the three wipe samples were above the primary numeric
criteria of 25 pg/iV. The third was below the detection limit. Concentrations of lead
in the two wipe samples, which exceeded the primary numeric criteria of 25 pgritg
were 38.9 pg/ff and 77 pg/tf.
Post P' Cleaning Samples, Test 4A - There were two air samples, seven micro
vacuum samples, and four wipe samples collected after the first cleaning. The two air
samples were below the numeric criterion of 1 pg/m\ Five of the seven micro
vacuum samples were below the detection limit and all seven samples were below the
comparison value. Two of the four wipe samples exceeded the primary numeric
criteria. Of the remaining two, one was below the numeric criterion and both were
below the detection limit.
Post P' Cleaning Samples, Test 4B - There were two air samples and four wipe
samples collected. The two air samples were below the primary numeric criteria of 1
pg/m\ Two of the four wipe samples exceeded the primary numeric criteria with
concentrations of 91.5 pg/lV and 79.3 pg/fV- Of the remaining two, one was, below
the numeric criterion and the other was below the detection limit.
Post P' Cleaning Samples, Test 4C - There were two air samples and seven micro
vacuum samples collected. The two air samples were below the primary numeric
criterion of 1 pg/m\ All seven micro vacuum samples were below the comparison
value of 25 pg/ft^ and six were below the detection limit.
Post P' Cleaning Samples, Test 4D - There were two air samples collected, with
results below the 0.051 pg/m^ detection limit as well as the numeric criteria of 1
pg/m\
Post Cleaning Samples, Test 4E - There were three wipe samples collected. Two of
the samples were broken at the laboratory; however, the laboratory was able to
analyze these samples and the results showed the samples to be below the primary
numeric criteria of 25 pg/ft\ The third sample exceeded the numeric criteria at a
concentration of 38.2 gg/ft^ This value is below the HUD/EPA action value of 40
pg/ft^ and this unit is not a residential area. Therefore, no additional cleaning or
testing was conducted.
108
CITY_21MC100_004205064
NYC-WTC_000276760
OCR can misread numbers and units. Confirm readings against the page image before using them.