NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 121 pages

COPCS report, NYC WTC chain of custody

Machine-extracted title · confidence 50%

Table of contents for contaminants of [name] report and building sections.

NYC-WTC_000276652–000276772
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

INTERNAL REVIEW DRAFT

Post J" Cleaning Samples, Test 4C - There were two air samples collected. Sampling results indicate that gypsum was not detected in air above the detection limit.

Lead Before Cleaning Samples - There were seven micro vacuum samples and three wipe samples collected. All seven micro vacuum samples were below the comparison value of 25 pgriL. Two of the three wipe samples were above the primary numeric criteria of 25 pg/iV. The third was below the detection limit. Concentrations of lead in the two wipe samples, which exceeded the primary numeric criteria of 25 pgritg were 38.9 pg/ff and 77 pg/tf.

Post P' Cleaning Samples, Test 4A - There were two air samples, seven micro vacuum samples, and four wipe samples collected after the first cleaning. The two air samples were below the numeric criterion of 1 pg/m\ Five of the seven micro vacuum samples were below the detection limit and all seven samples were below the comparison value. Two of the four wipe samples exceeded the primary numeric criteria. Of the remaining two, one was below the numeric criterion and both were below the detection limit.

Post P' Cleaning Samples, Test 4B - There were two air samples and four wipe samples collected. The two air samples were below the primary numeric criteria of 1 pg/m\ Two of the four wipe samples exceeded the primary numeric criteria with concentrations of 91.5 pg/lV and 79.3 pg/fV- Of the remaining two, one was, below the numeric criterion and the other was below the detection limit.

Post P' Cleaning Samples, Test 4C - There were two air samples and seven micro vacuum samples collected. The two air samples were below the primary numeric criterion of 1 pg/m\ All seven micro vacuum samples were below the comparison value of 25 pg/ft^ and six were below the detection limit.

Post P' Cleaning Samples, Test 4D - There were two air samples collected, with results below the 0.051 pg/m^ detection limit as well as the numeric criteria of 1 pg/m\

Post Cleaning Samples, Test 4E - There were three wipe samples collected. Two of the samples were broken at the laboratory; however, the laboratory was able to analyze these samples and the results showed the samples to be below the primary numeric criteria of 25 pg/ft\ The third sample exceeded the numeric criteria at a concentration of 38.2 gg/ft^ This value is below the HUD/EPA action value of 40 pg/ft^ and this unit is not a residential area. Therefore, no additional cleaning or testing was conducted.

108

CITY_21MC100_004205064

NYC-WTC_000276760

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276760Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000243565

EIA report for Law Department project at 100 Church Street by TRC.

Similar indexed content

Compare copies and versions →