INTERNAL REVIEW DRAFT I****, Commercial Unit; Retail Mattress Store - This is a 968 sq. ft. open space facing the World Trade Center site. All front windows were blown-in and excessive amounts of dust were present on all horizontal surfaces. Floor areas were covered with wall to wall carpeting and approximately 25 display mattresses and box springs were present. Ceiling tiles, mattresses, office equipment and flexible ventilation ducts were removed and disposed prior to cleaning. The space above the suspended ceiling exhibited the same characteristics as in the Chiropractors office.

Cleaning Method - This unit was subject to separate tests to evaluate 5 different cleaning techniques as described below:

Test 4A; Industrial HEPA filtered vacuums and AFD. Test 4B: Wet wipe all walls. Test 4C: Hot water carpet shampoo. Test 4D: A/C Duct Cleaning Test 4E: Cleaning of vinyl floor tile and window ledge wet wipe using water only.

Numeric Criteria - This unit met the numeric criteria listed in Table 1 for each compound after being cleaned once for each of the five different cleaning techniques.

Supplemental Sampling Activities - Prior to initiating pre-cleanup sampling activities as described below, EPA collected a bulk composite sample from the Mattress Store. The analytical data obtained from the bulk composite was utilized in identifying COPC concentrations present in settled dust, detennining the applicability of regulatory standards, and identifying potential health and safety concerns. The Mattress Store was selected, based upon visual observation, as being representative of a “worst case scenario” for the various units in the Confinnation Cleaning Study building.

Asbestos Before cleaning samples - Pre-cleaning air, micro vacuum, and wipe samples were collected for asbestos. The air samples were analyzed for PCM and TEM PCMe. The PCM results indicate that two of the samples were above the secondary numeric criterion of 0.01 f/cc and two samples were below this value. The TEM PCMe results indicate that two of the samples could not be analyzed due to overloading of particulate material. The remaining two samples were below the detection limit and below the primary numeric criterion of 0.0009 S/cc. All seven of the micro vacuum samples and all three of the wipe samples detected chrysotile.

Post P’ Cleaning Samples, Test 4A - Post-cleaning air, micro vacuum, and wipe were collected for asbestos. The air samples were analyzed for PCM, TEM AHERA, and

105

CITY_21MC100_004205061

NYC-WTC_000276757

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276757Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000243565

EIA report for Law Department project at 100 Church Street by TRC.

Similar indexed content

Compare copies and versions →