Gypsum
Before Cleaning Samples - There were no before cleaning samples collected.
Post Cleaning Samples - There were two post-cleaning air samples collected. The
results indicate that gypsum was not detected.
Lead
Before Cleaning Samples - There were no before cleaning samples collected.
Post J" Cleaning Samples - Two air samples were collected for lead. The results
indicate that lead was not detected in both samples.
Alpha-Quartz
Before Cleaning Samples - There were no before cleaning samples collected.
Post Cleaning Samples - There were two air samples collected after the first
cleaning. One sample exceeded the primary numeric criterion of 4 pg/m^. Alpha
quartz was not detected in the remaining sample.
Calcite
Before Cleaning Samples - There were no before cleaning samples collected.
Post J" Cleaning Samples - There were two air samples collected after the first
cleaning. Both samples were below the detection limit.
Cristobalite
Before Cleaning Samples - There were no before cleaning samples collected.
Post P' Cleaning Samples - There were two air samples collected after the first
cleaning. Both samples were below the detection limit.
Tridymite
Before Cleaning Samples - There were no before cleaning samples collected.
Post P' Cleaning Samples - There were two air samples collected after the first
cleaning. Both samples were below the detection limit.
MMVF
Before Cleaning Samples - There were no before cleaning samples collected.
Post Cleaning Samples - There were two pre-cleaning wipe samples collected.
The results for both samples were below the primary numeric criterion of 10 S/L.