Total Dust Before Cleaning Samples - There were no pre-cleaning samples collected.

Post P' Cleaning Samples - There were no samples collected after the first cleaning.

HVAC System - There was one micro vacuum sample and two wipe samples collected. The results for the micro vacuum sample indicate that dust was present below the numeric criterion of 0.50 mg/cm^ for this project. This value is lower than the numeric criterion set by the NADCA. EPA did not request analysis of the two wipe samples.

Liberty Street Stairwell - The stairwell consisted of cast concrete steps/landings, sheetrock walls and ceiling. All surfaces covered with gloss paint.

Cleaning method - This area was cleaned using test method 4A and test method 4B. Test method 4A used an industrial HEPA filtered vacuum and an AFD. Test method 4B consisted of a soap and water wet wipe of all horizontal and vertical surfaces.

Numeric Criteria - This area did not meet the numeric criterion for silica listed in Table 1. Due to a delay in receiving analytical result, this exceedance was not identified until after the close of the study. However, the only elevated sampling result for airborne silica was obtained from the Liberty Street staircase. This result is inconsistent with the other 53 samples taken throughout apartments and common spaces in the building. Those results were all reported to be below detection limits. Consequently, the presence of a single elevated sample result in a low occupancy area of the building is not indicative of a health hazard.

Asbestos Before Cleaning Samples - There were no before cleaning samples collected.

Post P' Cleaning Samples - Two post-cleaning air samples were collected for asbestos. These samples were analyzed for PCM, TEM AHERA, and TEM PCMe. The PCM results were all below the secondary numeric criterion of 0.01 f/cc. The TEM AHERA results indicate that one was below the detection limit and one was at the detection limit. Both samples were below the secondary numeric criterion of 0.022 S/cc. The TEM PCMe results indicate that one was below the detection limit and one was at the detection limit. Both samples were below the primary numeric criterion of 0.0009 S/cc.

103

CITY_21MC100_0 04205059

NYC-WTC_000276755

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276755Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000243565

EIA report for Law Department project at 100 Church Street by TRC.

Similar indexed content

Compare copies and versions →