Before Cleaning Samples - There was one pre-cleaning wipe sample collected. The
result indicates that lead was detected at a concentration above the primary numeric
criterion of 25 with a value of 10700 pg/ft^.
Post P' Cleaning Samples - There were three air samples collected after the first
cleaning. The results for all three samples were below the primary numeric criterion
of 1 pg/m\
HVAC System - There were three air samples and two wipe samples collected after
the HVAC system was cleaned. The air sample results indicate that all three air
samples were below the detection limit. The two wipe samples were above the
primary numeric criterion; however, the numeric criterion for lead in settled dust is
not designed to evaluate the interior surfaces of HVAC systems because they are
based upon hands and other body parts coming in direct contact with contaminated
surfaces, which would not occur in the HVAC system. Therefore, the air sample
results were used to determine compliance with the numeric criterion. In addition,
lead is used in the manufacturing of HVAC equipment, which makes the
identification of the source of the lead detected problematic (i.e., whether it is from
the dust or the building material).
Alpha-Quartz
Before Cleaning Samples - There was one pre-cleaning wipe samples collected. The
result indicates that alpha-quartz was detected above the detection limit.
Post P' Cleaning Samples - There were no samples collected after the first cleaning.
HVAC System - There was one air sample and two wipe samples collected for alpha
quartz. The air sample was below the detection limit. One of the wipe samples was
below the detection limit and the other sample was above the detection limit.
Calcite
Before Cleaning Samples - There was one pre-cleaning wipe samples collected. The
result indicates that calcite was present at a concentration that was above the detection
limit.
Post P' Cleaning Samples - There were no samples collected after the first cleaning.
H7AC System - There was one air sample and two wipe samples collected after the
HVAC system was cleaned. The results indicate that all of the samples were below
the detection limit.