Post 2"^ Cleaning - There were seven asbestos air samples collected after the second
cleaning. The samples were analyzed for PCM, TEM AHERA, and TEM PCMe.
The PCM results were all below the secondary numeric criterion of 0.01 f/cc and five
of the samples were below the detection limit. The TEM AHERA results were all
below the secondary numeric criterion of 0.022 S/cc with six of the seven samples
being below the detection limit. The TEM PCMe results were all below the primary
numeric criteria of 0.0009 S/cc with six of the seven samples being below the
detection limit and the seventh sample was at the detection limit of 0.0005 S/cc. This
indicates that the cleaning techniques were effective at removing particulate matter
after the first cleaning, which allowed valid asbestos air samples to be collected. The
air samples indicate that the unit met the primary and secondary numeric criteria.
HPACsamples - There were four asbestos air samples and two wipe samples
collected after the HVAC system was cleaned. The air samples were analyzed for
PCM, TEM AHERA, and TEM PCMe. The PCM results were all below the
secondary numeric criterion of 0.01 f/cc. The TEM AHERA results indicate that two
samples were below the detection limit and that two samples were equal to the
detection limit of 0.0005 S/cc. The TEM PCMe results indicate that all four samples
were below the detection limit of 0.0005 Fee.
The results for the two asbestos wipe samples indicate that both samples were below
the detection limit. The detection limit (12,100 S/cm^) was higher than the detection
limit (approximately 3,000. S/cnY) for most other wipe samples on this project.
Dioxin
Before Cleaning Samples - There were no samples collected and analyzed for dioxin.
Post P' Cleaning Samples - There were no samples collected and analyzed for dioxin.
HPAC Samples - There were no samples collected and analyzed for dioxin.
Gypsum
Before Cleaning Samples - There was one pre-cleaning wipe sample collected. The
result indicates that gypsum was not detected.
Post P' Cleaning Samples - There were no samples collected after the first cleaning
for gypsum.
HVAC Samples - There was one air sample and two wipe samples collected for
gypsum. The results for the air sample and wipe samples indicate that all three
samples were below the detection limit.