NYC-WTC_000319063
Asbestos air testing at 53 Park Place, including four locations, sampling date November 14, 2001.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗Summary of asbestos air testing results for 53 Park Place, including sampling dates and locations.
NYC-WTC_000275378–000275381OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Summary ofAsbestos Sampling Results Page 2 of 4 Address: 53 Park Place Date sampled: November 14, 200J
have been present, such as textiles or fiberglass, are counted along with the asbestos fibers, and the total fiber count is then compared to the asbestos standard. If the results were above 0.003 ficc using the PCM methodology, additional analysis was performed to determine whether any of the fibers were asbestos. This additional analysis was done for one of the residential air samples.
Results of Phase Contrast Microscopy (PCM) testing of air at 53 Park Place, Nov 14, 2001 Area Sampled Outside Common Residence 1 Residence 2
Sample Numbers A-C-1 A-Rl-1 A-R2-1 A-0-1
Concentration of Fibers in Air 0.001 <0.001 0.006 <0.001 at 53 Park Place (fi'cc)*
Concentration of Fibers (f/cc) <0.001 to 0.001 <0.001 to 0.002 <0.001 to 0.003 <0.001 to 0.003 in comparison locations NYC Re-occupancy 0.01 0.01 0.01 0.01 Standard (f/cc)** * f/cc is fibers in each cubic centimeter (cc) of air. This is calculated from the number of fibers seen on the air filter and the volume of air pulled through the filter measured in cubic centimeters of air. **New York City Department of Environmental Protection asbestos clearance criteria for post-abatement work (Rules of the City of New York, Title 15, Chapter 1)
Asbestos in air as determined by TEM analysis: TEM analysis is very specific and can distinguish between asbestos and non-asbestos fibers, such as textiles. This analysis determines if the fibers seen in the PCM analysis are asbestos, or if they are some other material. TEM analysis was conducted on all air samples that showed more than 0.003 f/cc in the air by PCM analysis. No asbestos fibers were found by the TEM analysis of the residence 1 air sample.
2 The TEM method employed here, NIOSH 7402, counts fibers of the same size as those detected by PCM analysis. Fibers reported here are greater than or equal to 5 microns in length and 0.25 microns in width.
CITY_21MC100_011108667
NYC-WTC_000275379
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000319063
Asbestos air testing at 53 Park Place, including four locations, sampling date November 14, 2001.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242804
Summary of asbestos air and dust results for Park Place building; multiple sample locations.
8 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000275435
Summary of asbestos air test results for 1125 Park Avenue, with locations and dust data.
6 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000319161
Asbestos air tests conducted inside/outside 258 Broadway; results summarized.
6 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000275386
Summary of asbestos air testing results for 258 Broadway, detailing locations sampled and analyses conducted.
6 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353959
Asbestos air/dust sampling results collected in a residential building; PCM analysis referenced.
6 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000275432
Summary of asbestos air test results for 301 East 61st Street, including fiber analysis.
6 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353888
Asbestos air and dust tests at multiple indoor locations; results summarize fiber content.
7 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353885
DOHMH sampling of asbestos in air at four locations inside/outside the building.
7 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000319462
Air test results for asbestos at 70 Battery Place; multiple indoor locations sampled.
6 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353882
Air tests for asbestos and associated fractions at 16 [name] building locations; indoor/outdoor results.
7 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000275407
Summary of asbestos air testing results for 450 [name] Avenue, including locations and analyses.
6 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000319063
Asbestos air testing at 53 Park Place, including four locations, sampling date November 14, 2001.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242804
Summary of asbestos air and dust results for Park Place building; multiple sample locations.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000275401
Summary of asbestos air testing results for 88 [name] Street, including locations and fiber analysis.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000176137
Summary report detailing air and settled dust sampling results from a residential building, including methods for fiber analysis.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000199617
A lab report detailing asbestos air and dust sampling results from four locations at a building on November 19, 2001.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000319526
Summary of asbestos air test results at 66 and 90 [name] buildings.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000319063
Asbestos air testing at 53 Park Place, including four locations, sampling date November 14, 2001.
Similar indexed content
NYC-WTC_000242804
Summary of asbestos air and dust results for Park Place building; multiple sample locations.
Similar indexed content
NYC-WTC_000275435
Summary of asbestos air test results for 1125 Park Avenue, with locations and dust data.
Similar indexed content
NYC-WTC_000319161
Asbestos air tests conducted inside/outside 258 Broadway; results summarized.
Similar indexed content
NYC-WTC_000275386
Summary of asbestos air testing results for 258 Broadway, detailing locations sampled and analyses conducted.
Similar indexed content