Asbestos sampling summary, 66/90 [name]

Machine-extracted title · confidence 34%

Summary of asbestos air test results at 66 and 90 [name] buildings.

NYC-WTC_000319526–000319528
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Summary ofAsbestos Sampling Results Page 2 of 3 Address: 66 Franlrfort St and 90 Gold St Date sampled: November 20, 2001

and the total fiber count is then compared to the asbestos standard. If the results were above 0.003 f/cc using the PCM methodology, additional analysis was performed to determine whether any of the fibers were asbestos. In this building, additional analysis was not warranted since the air sampling results in your building were not greater than 0.003 f/cc.

Results of Phase Contrast Microscopy (PCM) testing of air at 66 Frankfort St and 90 Gold St., November 20, 2001 Area Sampled Outside Common Residence 1 Residence 2 Sample Numbers A-Rl-11 A-R2-11 A-0-11 A-C-11 A-C-X-11 * Concentration of Fibers in Air <0.001 <0.001 <0.001 <0.001 At this location (f/cc)** <0.001 * Concentration of Fibers in Air <0.001 to 0.001 <0.001 to 0.002 <0.001 to 0.003 <0.001 to 0.002 at comparison locations (f/cc)

NYC Re-occupancy Standard 0.01 0.01 0.01 0.01 (f/cc)*** * Denotes a second air sample was taken at the same location for quality control purpose. ** f/cc is fibers in each cubic centimeter (cc) of air. This is calculated from the number of fibers seen on the air filter and the volume of air pulled through the filter measured in cubic centimeters. *** New York City Department of Environmental Protection asbestos clearance criteria for post-abatement work (Rules of the City of New York. Title 15, Chapter 1)

ASBESTOS DUST TEST RESULTS

The dust and debris samples were examined by two different laboratory methods for asbestos fibers, Polarized Light Microscopy (PLM) and Transmission Electron Microscopy (TEM). PLM is used to define asbestos containing material in dust and debris. A material is considered to be asbestos containing material if it contains more than 1% asbestos using the PLM method. The PLM method only counts the larger asbestos fibers. TEM analysis can detect smaller fibers, but is not used for regulatory purposes on dust samples.

Asbestos was not detected in the indoor dust samples using the PLM method. Further analysis of the indoor dust by the more specific TEM method detected some asbestos in the unoccupied residences. Therefore the matter was referred to the New York City Department of Environmental Protection for follow-up inspection. One of the residences had not been cleaned since the collapse of the World Trade Center and it was unclear whether the other residence had been cleaned recently or not.

No asbestos was detected in the settled dust from the lobby by either method. Not enough dust was available for sampling in the outdoor area.

CITY_21MC100_002452768

NYC-WTC_000319527

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000319527Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000319462

Air test results for asbestos at 70 Battery Place; multiple indoor locations sampled.

Similar indexed content

Compare copies and versions →