Summary of Asbestos Sampling Results Page 2 of 3
Address: 66 Frankfort St and 90 Gold St Date sampled: November 20, 2001
and the total fiber count is then compared to the asbestos standard. If the results were above
0.003 f/cc using the PCM methodology, additional analysis was performed to determine whether
any of the fibers were asbestos. In this building, additional analysis was not warranted since the
air sampling results in your building were not greater than 0.003 f/cc.
Results of Phase Contrast Microscopy (PCM) testing of air at 66 Frankfort St and 90 Gold St.,
si ovember 20, 200!
Area Sampled Outside Common Residence 1 Residence 2
Sample Numbers
A-0-11 A-C-11 A-Rl-11 A-R2-11
A-C-X-11 *
Concentration of Fibers in Air
<0.001 <0.001 <0.001 <0.001
At this location (f/cc)**
<0.001 *
Concentration of Fibers in Air <0.001 to 0.001 <0.001 to 0.002 <0.001 to 0.002 <0.001 to 0.003
It comparison locations (f/cc)
NY C Re-occupancy 0.01 0.01 0.01 0.01
Standard (f/cc)***
* Denotes a second air sample was taken at the same location for quality control purpose.
** f/cc is fibers in each cubic centimeter (cc) of air. This is calculated from the number of fibers seen on the air
filter and the volume of air pulled through the filter measured in cubic centimeters.
*** New York City Department of Environmental Protection asbestos clearance criteria for post-abatement work
(Rules of the City of New York, Title 15, Chapter 1)
ASBESTOS DUST TEST RESULTS
The dust and debris samples were examined by two different laboratory methods for asbestos
fibers, Polarized Light Microscopy (PLM) and Transmission Electron Microscopy (TEM). PLM
is used to define asbestos containing material in dust and debris. A material is considered to be
asbestos containing material if it contains more than 1% asbestos using the PLM method. The
PLM method only counts the larger asbestos fibers. Therefore, if results by PLM were not greater
than 1% asbestos, the sample was then analyzed by the TEM method that does count the smaller
fibers. However, TEM analysis is not used for regulatory purposes for dust samples.
Asbestos was not detected in the indoor dust samples using the PLM method. Not enough dust
was available for sampling in the outdoor area. Further analysis of the indoor dust by the more
specific TEM method detected some asbestos in the unoccupied residences. One of the
residences had not been cleaned since the collapse of the World Trade Center and it was unclear
whether the other residence had been cleaned recently or not. No asbestos was detected in the
settled dust from the lobby by either method.