Summary ofAsbestos Sampling Results Page 3 of 3
Address: 66 Franlrfort St and 90 Gold St Date sampled: November 20, 2001
Fibrous materials in dust found by PLM analysis: Polarized Light Microscopy identifies
asbestos fibers by shape and optical characteristics. Other fibers such as fabric (synthetics),
paper
(cellulose) and fiberglass may be identified in the analysis. The laboratory analyst counts the
fibers present to give an estimate of fiber content. PLM is used for regulatory purposes for dust
samples.
Results of Polarized Light Microscopy (PLM) testing of dust at 66 Frankfort St and 90 Gold St.,
November 20, 2001
Area Sampled [Outside Common Residence 1 Residence 2
Sample Numbers Io Dust Available VA-C-11 VA-Rl-11 VA-R2-11
Asbestos fibers (%) Io Dust Available None Detected None Detected None Detected
____
Asbestos in dust as determined by TEM analysis: TEM analysis was conducted on all dust
samples that showed asbestos content by PLM as less than 1%. TEM analysis is very specific,
can detect smaller fibers of asbestos, and is subject to less interference. This analysis was done
to confirm the PLM findings of no asbestos found. However, TEM analysis is not used for
regulatory purposes for dust samples.
Results of Transmission Electron Microscopy (TEM) testing of dust at 66 Frankfort St and
90 Gold St., November 20, 2001
Area Sampled [Outside Common Residence 1 Residence 2
Sample Numbers fo Dust Available VA-C-11 VA-Rl-11 VA-R2-11
Asbestos fibers (%) ^o Dust Available None Detected < 1% 1.5%