Page image not rendered yet. The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
7
'i
rec’d from Janet Fox, ConEd 9/25/01
DATA SUMMARY as of 9/25/01 1.00 PM
On September 11, Con Edison EHS Department initiated a Sampling Plan for asbestos
bulk sampling, area monitoring and personnel monitoring. Sampling and analysis is being
performed by our company lab and outside labs, ATC, Air Tech and Sci-Lab under the
direction of the Industrial Hygienists of Corporate EHS.
The following is a summary of the data to date;
Bulk Sample results:
36 samples taken - samples range from ND to 1.5 % asbestos
- 34 samples <1.0% asbestos
- 2 > 1% asbestos were 1.3% and 1.5%
- samples > 1.0 % located at West St. and Watt and West
St. south of Vesey St.
Area Sample results:
87 samples taken - sample range from <0.002 to 0.23 free
(1 sample invalid
2 unable to quantify) - sample duration from 30 to 240 minutes
- 10 of 84 Samples > O.Olfrcc; one sample after 9/15
- 1 of 10 Samples > 0.01 was 0.230 free (PCM) at Park
Place and West Broadway on 9/15. TEM on this sample
was verified at 0.362 s/cc.
Same location resampled on 9/18, results were
0.003 and 0.004 free (PCM)
-14 Samples of 84 Samples at 0.01
, - 60 Samples of 84 Samples at <0.01
- 5 area samples of 68 Samples taken since 9/18/01 are
>0.01 /cc ( 0.02, 0.015, 0.012, 0.012, 0.015 PCM)
- There were 3 TEM analyses (structures/cc) with results
of <0.0548, 0.3627 and 0.0009 structures per cc
CITY_21MC100_006814658
NYC-WTC_000275295
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000275295Source: NYC Law Department, mirrored locally