Asbestos air sampling lab report, World Trade Center site, Sep

Machine-extracted title · confidence 95%

Laboratory analysis of asbestos air samples collected at the World Trade Center site on September 19-22, 2001.

NYC-WTC_000186549
Page image
Scanned page image, NYC-WTC_000186549
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

U.S. Environmental Protection Agency 'Sampling Situation Report Sunday, September 23, 2001 ( 2:00 pm)

Fixed Ambient Air Sampling Locations (Asbestos)

NYC / ER (Sept. 19, 10 AM - 8PM) o 13 samples (including 1 duplicate) analyzed by PCM showed that 10 of these 13 samples were at or above the OSHA standard (0.01 free) for PCM. Upon confirmatory TEM analysis 2 samples out of 10 were greater than the AHERA standard (70S/mm^). (Note; Sample volumes collected were lower than the recommended volumes. When normalized to 1200 liter volume, 2 samples exceeded the AHERA standard of 70S/mm^) o These two samples results were 76.78 and 76.93 s/mm2 and were at locations B (Intersection of Church and Dey) and E (Intersection of Liberty and South End Avenue). Both these samples are within the immediately impacted area.

Fixed Ambient Air Sampling Locations (Asbestos)

NYC / ER (Sept.21-22, 4PM - 4AM) O 13 samples (including 1 duplicate) analyzed by PCM showed only 1 of these samples marginally exceeding the OSHA standard (0.01 f/cc) for PCM. Upon confirmatory TEM analysis no exceedance of the AHERA standard (70S/mm^) was noted. (Note: Sample volumes collected were lower than the recommended volumes. When normalized to 1200 liter volume, no samples exceeded the AHERA standard of 70S/mm\)

New Jersey O Sept 20 - all 4 samples showed less than detectable levels

NYC BulkZDust Samples

® One sample taken from the Tower 2 Beam on Sept. 21 had non-detectable levels of asbestos

Landfill Air Sampling locations (Asbestos and PM)

e 10 air samples taken on Sept. 22 had no detectable levels of asbestos Dust continues to be monitored at the site for dust suppression measures through the use of personal monitors

Direct Reading Instruments • Nothing of significance identified.

Ambient Sampling & Rector Street Runoff Resampling

Results from metals, PAHs and TSS analysis showed no exceedances of levels of concern

CITY_21MC100_002941063

NYC-WTC_000186549

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000186549Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →