7
Personal Sample Results:
252 samples taken - sample range from <0.01 to 2.114 free (PCM)
(6 samples invalid) - sample duration from 30 to 340 minutes
-212 samples of 229 were < O.lfre (PCM)
I - 34 samples of229 were >0.1 free (PCM)
-1 sample >1.0 free was 2.110 free (PCM)
TEM analysis was 0.144 total structures/ee.
- elevated levels >0. Ifree for work;
o walking - 0.01 to 0.66 free
o pulling eable - 0. 0013 to 2.114 free
o turning valves - 0.032 to 0.294 free
o cut/eap gas main - 0.020 to . 131 free
oboxing eable - 0.01 to 0.111 free
- There were 15 TEM analyses (structures/mm2)
with results ranging from <2.5 to 15.0 struetures per
mm2
- There were 27 TEM analyses (struetures/cc) with
results ranging from 0.0035 to 0.144 struetures per
ee
NOTE. LEVELS HAVE GOTTEN PROGRESSIVELY LOWER AS STREETS AKE
CLEANED AND DUST REMOVED. THE HIGHEST LEVELS WERE DURING THE
FIRST FEW DAYS.
Real time respirable dust monitorins: conducted on 9/15 through 9/20 using the MIE
Portable Data Ram Dust Monitor with size cutoff point of 10 microns,
9/15 TWA for 110 minutes was 0.296 mg/m3
9/17 TWA for 90 minutes was 0.342 mg/m3 342.
9/18 TWA for 110 minutes was 0.296 mg/m3 CAt
9/19 TWA for 270 minutes was 0.116 mg/m3 [
02, CO, Combustibles, and H2S monitorins: conducted on 9/17, 9/18 and 9/19 with
RKI Four-Runner and RKI Eagle showed at all locations (street and manhole) all levels
normal, and hydrogen sulfide not detected.
Noise Monitorins in immediate areas where diesel generators located - range from 82
dBA to 93 dBA. (Instrument B&K Investigator Sound Level Meter)
VOCs conducted on 9/18 and 9/19 using real-time PID with a 10.6 ev. lamp ~ none
detected
Attached is the most recent WTC Sample report, as of 1:00 pm on 9/25/01
CITY_21MC1OO_OO6814659
NYC-WTC_000275296
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000275296Source: NYC Law Department, mirrored locally
Air sampling results for asbestos at NYC Emergency Response locations, showing all samples below TEM AHERA standard and notes on low volumes or access issues.
57-page lab report documenting World Trade Center environmental test results distributed to multiple federal, state, and local agencies including CDC and EPA.