Scope of Work
ATC Associates. Inc. (ATC) was retained by New York City Board of Education (NYC-
BOE) to collect dust wipes to be analyzed for lead content. Dust wipe samples were
collected from locations inside the school building and from the outdoor playground
indicated by the Parents Association environmental consultant Mr. Tom Fusillo of
ENVIRON.
The purposed of the dust wipe sampling is to determine if settled dust contains lead.
ATC’s representative Ms. Mariana Medinets visited P.S. 89M located at 201 Warren
Street, New York, NY on January 11"’, 2002. Dust wipe.s to be analyzed for lead content
were collected from locations indicated to ATC by the parents association environmental
consultant Mr. Tom Fusillo of ENVIRON and as specified by the New York City Board
of Education Environmental Health & Safety Unit and in accordance with HUD
protocols.
LEAD-IN-DUST SAMPLING
Lead-in-dust threshold levels
The New York City Health Code, part 173.14 and the Federal Departments of Housing and
Urban Development (HUD) and Environmental Protection Agency (EPA) have established
acceptable lead-in-dust levels for re-occupancy after a lead abatement has occurred
(commonly referred to as “final clearance” levels). As stated in the Code, final clearance
after abatement has taken place is achieved when dust wipe samples indicate lead levels
below those listed below:
For Windowsills: 250 pg/ft"
For Floors: 40 pg/ft-
Although the lead-in-dust samples collected at P.S. 89M were not collected in response to
lead abatement, the same thresholds are used since no other regulations or standai’ds are
applicable to this project.
Sampling Methodology
ATC provided all laboratory analytical services in support of this limited inspection. ATC
is certified by the New York State Department of Health’s Environmental Laboratory
Accreditation Program to perform lead and related analyses of environmental samples
(Laboratory ID Number: 10879). The laboratory utilizes the United States Environmental
Protection Agency analysis method number SW846-7420 and the National Institute of
Occupational Safety and Health method number 7082M.
The lead-in-dust samples were obtained by gently wiping a pre-measured surface area
with non-alcohol moistened towelettes. ATC’s representative wore disposable gloves; a
new glove was worn with each new sampling procedure, and care was taken to avoid
P.S. S9M
<S2ftTC January / 7. 2002