NYC Law Department release
Independent mirror · updated as the City releases more · v1.3.2
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

Limited lead-in-dust wipe sampling report, PS 89M, Jan 2002

Machine-extracted title · confidence 95%

Report prepared for the NYC Board of Education detailing limited lead-in-dust wipe sampling results at PS 89M in January 2002.

NYC-WTC_000174740–000174742
Page image
Scanned page image, NYC-WTC_000174741
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Scope of Work

ATC Associates, Inc. (ATC) was retained by New York City Board of Education (NYC- BOE) to collect dust wipes to be analyzed for lead content. Dust wipe samples were collected from locations inside the school building and from the outdoor playground indicated by the Parents Association eiiviroiunental consultant Mr. Tom Fusillo of ENVIRON.

The purposed of the dust wipe sampling is to determine if settled dust contains lead.

ATC’s representative Ms. Mariana Medinets visited P.S. 89M located at 201 Warren Street, New York, NY on January 11*, 2002. Dust wipes to be analyzed for lead content were collected from locations indicated to ATC by the parents association environmental consultant Mr. Tom Fusillo of ENVIRON and as specified by the New York City Board of Education Environmental Health & Safety Unit and in accordance with HUD protocols.

LEAD-IN-D UST SAMPLING

Lead-in-dust threshold levels The New York City Health Code, part 173.14 and the Federal Departments of Housing and Urban Development (HUD) and Environmental Protection Agency (EPA) have established acceptable lead-in-dust levels for re-occupancy^ after a lead abatement has occurred (commonly referred to as '‘final clearance” levels). As stated in the Code, final clearance after abatement has taken place is achieved when dust wipe samples indicate lead levels below those listed below:

For Windowsills: . 250 pg/ff For Floors: 40 pg/ft"

Although the lead-in-dust samples collected at P.S. 89M were not collected in response to lead abatement, the same thresholds are used since no other regulations or standards are applicable to this project. '

Sampling Methodology ATC provided all laboratory analytical services in support of this limited inspection. ATC is certified by the New York State Department of Health’s. Eiiviroiunental Laboratory Accreditation Program to perform lead and related analyses of environmental samples (Laboratory ID Number: 10879). The laboratory utilizes the United States Environmental Protection Agency analysis method number SW846-7420 and the National Institute of Occupational Safety and Health method number 7082M.

The lead-in-dust samples were obtained by gently wiping a pre-measured surface area with non-alcohol moistened towelettes. ATC’s representative wore disposable gloves; a new glove was worn with each new sampling procedure, and care was taken to avoid P.S. 89M January 17, 2002

CONFIDENTIAL, SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008 CITY_21 MC100_014660071

NYC-WTC_000174741

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000174741Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →