Limited lead-in-dust wipe sampling, PS 89M

Machine-extracted title · confidence 58%

Lead-in-dust wipe sampling report for PS 89M in NYC public schools.

NYC-WTC_000274805–000274827
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Scope of Work

ATC Associates, Inc. (ATC) was retained by New York City Board of Education (NYC- BOE) to collect dust wipes to be analyzed for lead content. Dust wipe samples were collected from areas throughout the interior and exterior of the school building as indicated to ATC by the Parents Association environmental consultant representative Mr. Tom Fusillo of ENVIRON Corp, and approved by NYC- BOE.

The purposed of the dust wipe sampling is to determine if dust inside and outside the school contains lead.

ATC’s representative Ms. Mariana Medinets visited P.S. 89M located at 201 Warren Street, New York, NY on February 22"'', 2002. Dust wipes to be analyzed for lead content were collected from areas throughout the interior and exterior of the school building indicated to ATC by ENVIRON and as specified by the New York City Board of Education Environmental Health & Safety Unit and in accordance with HUD protocols.

LEAD-IN-DUST SAMPLING

Lead-in-dust threshold levels The New York City Health Code, part 173.14 and the Federal Departments of Housing and Urban Development (HUD) and Environmental Protection Agency (EPA) have established acceptable lead-in-dust levels for re-occupancy after a lead abatement has occurred (commonly referred to as “final clearance” levels). As stated in the Code, final clearance after abatement has taken place is achieved when dust wipe samples indicate lead levels below those listed below:

For floors; 40 For windowsills: 250 (.ig/ft- For window wells: 400 pg/ft^ For exterior concrete surfaces: 800 pg/fe

Although the lead-in-dust samples collected at P.S. 89M were not collected in response to lead abatement, the same thresholds are used since no other regulations or standards are applicable to this project.

Sampling Methodology ATC provided all laboratory analytical services in support of this limited inspection. ATC is certified by the New York State Department of Health’s Environmental Laboratory Accreditation Program to perform lead and related analyses of environmental samples (Laboratory ID Number: 10879). The laboratory utilizes the United States Environmental Protection Agency analysis method number SW846-7420 and the National Institute of Occupational Safety and Health method number 7082M.

P.S. 89M Pebniary 25. 2002

CITY_21MC1OO_OO9O17747

NYC-WTC_000274806

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000274806Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →