NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

TEM analysis, New Stuyvesant H.S., Lab 5748

Machine-extracted title · confidence 39%

TEM asbestos analysis with SAED/EDS; sample 62067, exterior/interior of building.

NYC-WTC_000270762
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010 N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report -Date: 10/24/01 ASBESTOS FIBER Ty^ALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: T^ERA Final Rule, EPA Federal Register (40 CFR. Part 763), Vol. 52, No. 210, October 30, 1987

Santple Identification ymalysis Parameters

Project/Site; New Stuyvesant H.S.,'345 Chambers St., NY, NY TEM Sample No.: 5748 - 62067 Exterior & Interior of Building & Roof Date Received: 10/23/01 Grid Openings Analyzed:__ 4

Project Sample No.: 13 Average Grid Opening: 106.00 urn

Air Volume :2,920 HXers Total Area Analyzed: 0.0450 mm2

Filter Type: MCE 25 mm diam. Pore Size; 0.45 urn Analytical Sensitivity:22^2 s/mrta Effective Area: 385 mm2 0.004S s/cc

FIBROUS PARTICULATES 7VNALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct >=5um Struct/mTn2 Struct/cc nqm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The ‘estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED); None detected Amphibole Asbestos Type: None detected The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.b. Director of Electron Microscopy

CITY_21MC100_011107763

NYC-WTC_000270762

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000270762Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000293820

TEM analysis of exterior/interior building samples; SAED/EDS; Received 10/22/01.

Similar indexed content

NYC-WTC_000270877

TEM asbestos analysis; exterior/interior, sample 10.

Similar indexed content

NYC-WTC_000294005

Asbestos fiber analysis by TEM with SAED/EDS for New Stuyvesant H.S. site, Oct 2001.

Similar indexed content