TEM report, New Stuyvesant HS exterior/interior

Machine-extracted title · confidence 28%

TEM analysis of air samples from exterior and interior areas at New Stuyvesant High School; AHERA method.

NYC-WTC_000293565
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/16/01

ASBESTOS FIBER 7\NALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register 140 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

SaTTOoIe Identification Analysis Parameters

Proj ect/Site: New Stuyvesant H..S., 345 Chambers St., NY, NY TEM Sample No.: 5698 61334 Exterior & Interior of Building & Roof Date Received: 10/15/01 Grid Openings Analyzed:__4

■ Project Sample No.: NSHS-SIR-lO/lS-Ol Average Grid Opening:, 106.00 um

Air Volume :^lJ90iu,t^rs Total Area Analyzed : 0^04 5^mm2

Filter Type: MCE 25 mm diam, , Pore Size: 0.45 um Analytical Sensitivity Effective Area: 385 mm2 0■0045 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. struct >=5uni Struct/mm2 Struct/cc ngTn/m3

Chrysotile Asbestos 0 0 0 0 0 0 0. 0 0.OOOC 0

Amphibole Asbestos 0 0 0 0 0 0 0. 0 0.0000 0

Ambiguous 0 0 0 0 0 0 0. 0 0.0000 0

Total asbestos (includes ambiguous structures) 0 c 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003082222

NYC-WTC_000293565

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000293565Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000293820

TEM analysis of exterior/interior building samples; SAED/EDS; Received 10/22/01.

Similar indexed content

NYC-WTC_000293369

TEM asbestos fiber analysis from New Stuyvesant High School exterior/building site, received 10/06/01.

Similar indexed content

NYC-WTC_000270723

TEM analysis with SAED/EDS for New Stuyvesant High School, received 10/22/01.

Similar indexed content

Compare copies and versions →