JLC ENVIRONMENTAL CONSULTANTS, INC.
200 Park Avenue South, Suite 1001, New York, New York 10003
Phone; (212) 420-8119 Fax; (212) 420-6092
Project No.; 01-2102
Metcalf a Eddy Inc. ELAP Lab Code: 11029
Analyte; ASBESTOS
3 Werner Way, Suite 310 NIOSH and AIHA Lab Cede: 100273 Dale Received: 9/28/01
Lebanon, NJ 08833 NVLAP Lab Code: 101953
Date Analyzed; 9/29/01
SUMMARY OF ANALYTICAL RESULTS - PLM Batch If: 0109B385
Site; 3 World Financial Center- Floors 3-26
SAMPLE #
DATE COLOR ASBESTOS TOTAL % OF CONSTITUENTS
DESCRIPTION / LOCATION DETECTED? ASBESTOS CONSTITUENTS
COLLECTED
LAB#
CLIENT'S SAMPLE #
10009 10th Floor/ South East/ South East GRAY TRACE <1% CHRY <1%
9/28/01 Passage \Nay/ Sample of Debris CELL 25%
10995 FBGL 15%
NFIB 60%
10-009
INSUFFICIENT MATERIAL SUBMITTED **TEM RECOMMENDED “NOT ANALYZED POSITIVE STOP
Sample Ajiatysis by. ASBESTOS CONSTITUENTS NON-ASBESTOS CONSTITUENTS
Polarized Light Microscopy-Dispersion Staining (PLM-DS) CHRY = Chtysolile Asbestos PAPF = Paper Fiber
AMOS = AmosHe Asbestos MINW = Mineral Wool
CROC = Crocidolite Asbestos FBGL = Fiberglass
Method of Sample Preparation end Analysis:
ACTN = Actinolite Asbestos SYNF = Synthetic Fibers
All samples were prepared and analyzed in accordance with the EPA TREM = Tremolite Asbestos CELL = Cellulose
■Method for the Determination of Asbestos in Bulk Building Materials” ANTH = Anihophylile Asbestos NFIB = Non-Fibrous
USEPA/ 600/ R-93/116, July 1993. ORGM = Organic Materia!
WOLL = Wollastonite
Instrumentation: HSHR = Horse Hair
OTHR = Other
Olympus PLM, Model BH-Z/VM Steieomicroscope, Model
VMZ1X-4X. . "Gularn Machhiwala
Laboratory Director
Anatylical results reflect the make up of the materials only in the areas sampled. This "Summary of Analytical Results" shall not be reproduced except In full, without the wrilto
approval of JLC Laboratory, and it must not be used by client to claim product endorsement by NVIAP or any agency of the U.S. Government. This method is not applicable to
samples containing large amounts of fine fibers below the resolution of the light microscope.' The value of this method is limited Io the quantitative identification of asbestos
and the semi-quantitative determination of asbestos content of bulk samples, expressed as a percentage of the protected'area. Quantitation of asbestos content was
determined with a visual volume estimate, a calibrated visual area.estimate, and/or point counting procedure. CAUTION: Other fibers with optical properties similar to asbestc ■
may give positive interferences and will bo considered asbestos under this methodology. Also, PLM is not consistently reliable in detecting asbestos in floor coverings and
similar non-friable organically-bound rrtalerials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can b
considered or treated as non-asbestos containing.