NYC 9/11 Public Portal Document
JLC ENVIRONMENTAL CONSULTANTS. INC.
200 Park Avenue South, Suite 1001, New York, New York 10003
Phone: (212) 420-8119 Fax: (212) 420-6092
Project No.: 01-2102
Metcalf 8 Eddy Inc. ELAP Lab Code: 11029
Arialyte: ASBESTOS
3 Werner Way, Suite 310 NIOSH and AIHA Lab Code: 100273
Date Received: 9/28/01
Lebanon, NJ 08833 NVLAP Lab Code. 101953
Date Analyzed: 9/29/01
Batch #: 0109B385
SUMMARY OF ANALYTICAL RESULTS - PLM
Site: [ 3 World Financial Center - Floors 3-26
SAMPLE #
COLOR ASBESTOS TOTAL % OF CONSTITUENTS
DATE DESCRIPTION / LOCA TION DETECTED? ASBESTOS CONSTITUENTS
COLLECTED
LAB#
CLIENT'S SAMPLE #
7009 7th Floor/ South East Corner/ Passage BROWN NO 0% CELL 30%
9/28/01 Way/ Sample of Debris NFIB 70%
11025
7-009
•INSUFFICIENT MATERIAL SUBMITTED •TEM RECOMMENDED *~NOT ANALYZED POSITIVE STOP
Sample Analysis by: ASBESTOS CONSTITUENTS NON-ASBESTOS CONSTITUENTS
Polarized Light Microscopy-Dispersion Staining (PLM-DS) CHRY = ChrvsotileAsbestos PAPF = Paper Fiber
/\MOS = Amosite Asbestos MINW = Mineral Wool
Method of Sample Preparation and Analysis: . CROC = Crocidolrte Asbestos FBGL = Fiberglass
ACTN = Actinolile Asbestos SYNF= Synthetic Fibers
/Ml samples were prepared and analyzed in accordance with the EPA ' TREM = Tremolite Asbestos CELL = Cellulose
■Method for the Determination of /tebestos in Bulk Building Materials" ANTH = Anthophytite Asbestos NFIB = Non-Fibrous
USEPA/ 600/ R-93/116, July 1993.
ORGM = Organic Material
WOLL = Wollaslonite
Instrumentation: HSHR = Horse Hair
-------- by' f W OTHR = Other
Olympus PLM, Model BH-2/VM Stereomicroscope, Model
VMZ 1x-4x. Gulam Machhiwala
Laboratory Director
/Mialytical results reflect the make up of the materials only in the areas sampled. This "Surrimary of /Analytical Results" shall not be reproduced except in full, without the writfe
• approval of JLC Laboratory, and 3 must not be used by client Io claim product endorsement by NVLAP or any agency of the U.S. Government. This method is not appScable to
samples containing large amounts of fine fibers below the resolution of the light microscope. The value of this method is limited to the quantitative identification of asbestos
• and the semi-quantitative determination of asbestos content of bulk samples, expressed as a percentage of the protected area. Quantitation of asbestos content was
determined with a visual volume estimate, a calibrated visual area estimate, and/or point counting procedure. CAUTION: Other fibers with optical properties similar Io asbestc-
may give positive interferences and will be considered asbestos under this methodology. /Mso, PLM is not consistently reliable in detecting.asbestos in (loor coverings and
similar non-friable organically-bound materials. Quantitative transmission electron microscopy is cunenlly the only method that can be used to determine if this material can b
rxrnsidered or treated as non-asbestos containing.
Page 3 of 3