NYC 9/11 Public Portal Document
JLC ENVIRONMENTAL CONSULTANTS, INC.
200 Park Avenue South, Suite 1001, New York, New York 10003
Phone: (212) 420-8119 Fax: (212) 420-6092
Project No.; 01-2102
Metcalf & Eddy Inc. ELAP Lab Code: 11029
Analyte: ASBESTOS
3 Werner Way, Suite 310 NIOSH and AIHA Lab Cede: 100273
Date Received: 9/28/01
Lebanon, NJ 08833 NVLAP Lab Code: 101953
Date Analyzed: 9/29/01
SUMMARY OF ANALYTICAL RESULTS - PLM Batch #: 0109B385
Site: [ 3 World Financial Center - Floors 3-26
L
SAMPLE #
DATE COLOR ASBESTOS TOTAL % OF CONSTITUENTS
DESCRIPTION ILOCA TION DETECTED? ASBESTOS OUNSTIIUENIS
COLLECTED
LAB#
CLIENT'S SAMPLE #
7005 7th Floor/ South East Corner/ Central - BEIGE NO 0% CELL 20%
9/28/01 East/ Sample of Debris NFIB 80%
11021
7-005
7006 7th Floor/ South East Corner/ West/ GRAY NO 0% . CELL 15%
9/28/01 Sample of Debris NFIB 75%
11022
7-006
7007 7th Floor/ South East Corner/ Passage GRAY NO 0% FBGL 25%
9/28/01 Way/ Sample of Debris NFIB 75%
11023
7-007
7008 7th Floor/ South East Corner/ Passage GRAY NO 0% FBGL. 20%
9/28/01 Wa'^l Sample of Debris NFIB 80%
11024
7-008
HNSUFFICIENT MATERIAL SUBMITTED “TEM RECOMMENDED —NOT ANALYZED POSITIVE STOP
Sample Analysis by: ASBESTOS CONSTITUENTS NON-ASBESTOS CONSTITUENTS
Polarized Light Microscopy-Dispersion Staining (PLM-DS) CHRY = Chrysotile Asbestos PAPF = Paper Fiber
AMOS = AmosHe Asbestos MINW= Mineral Wool
Method of Sample Preparation and Analysis: CROC = Crocidolite Asbestos FBGL = Fiberglass
ACTN = Actinolite Asbestos SYNF = Synthetic Fibers
All samples were prepared and analyzed in accordance with the EPA TREM = Tremolite Asbestos CELL = Cellulose
"Method for the Determination of Asbestos in Bulk Building Materials' ANTH = Anthophylite Asbestos NFIB = Non-Fibtous
USEPA/600/R-33/116, July 1993.
ORGM = Organic Material
WOLL = Wollastonite
Instrumentation: HSHR = Horse Hair
OTHR = Other
Olympus PLM, Model BH-2/VM Stereomicroscope, Model
VMZ 1x-4x. Gulam Machhiwala
Laboratory Director
Analytical results reflect the make up of the materials only in the areas sampled. This "Summary of Analytical Results" shall not be reproduced except in full, without the writle
approval of JLC Laboratory, and it must not be used by client Io claim product endorsement by NVLAP or any agency of the U.S. Government This method iS not applicable to
samples containing large amounts of fine fibers below the resolution of the light microscope. The value of this method is limited to the quantitative idenliTication of asbestos
and the semi-quantitative determination of asbestos content of bulk samples, expressed as a percentage of the protected area. Quantitation of asbestos content was .
determined with a visual volume estimate, a calibrated visual area eslimafe, and/or point counting procedure. CAUTION: Other fibers with optical properties similar to asbesto
may give positive interferences and will be considered asbestos under this methodology. Also, PLM is not consistently reliable in detecting asbestos in floor coverings and
similar non-friable organically-bound materials. Quantitalive transmission electron microscopy is currently the only method that can be used to determine if this material can b
considered or treated as non-asbeslos containing.
Page 2 of 3
CITY_21MC1OO_OO2821O44
NYC-WTC_000268954
OCR can misread numbers and units. Confirm readings against the page image before using them.